{"title":"Effects of nontransposed lines and unbalanced loads on state estimation","authors":"S. Zhong, A. Abur","doi":"10.1109/PESW.2002.985151","DOIUrl":null,"url":null,"abstract":"This paper investigates the errors introduced in the positive sequence state estimation due to the usual assumptions of having fully balanced bus loads/generations and continuously transposed transmission lines. A three-phase state estimator is first developed in order to verify the actual error free solution in the phase coordinates. Then, several tests are conducted using different assumptions regarding the availability of single and multi-phase measurements. It is demonstrated that incomplete metering of three-phase system quantities may lead to significant errors in the positive sequence state estimates for certain cases. Such cases may also lead to incorrect bad data detection and elimination, further deteriorating the quality of the state estimate. IEEE 30 bus test system is used to illustrate these cases.","PeriodicalId":198760,"journal":{"name":"2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309)","volume":"83 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2002-08-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESW.2002.985151","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 54

Abstract

This paper investigates the errors introduced in the positive sequence state estimation due to the usual assumptions of having fully balanced bus loads/generations and continuously transposed transmission lines. A three-phase state estimator is first developed in order to verify the actual error free solution in the phase coordinates. Then, several tests are conducted using different assumptions regarding the availability of single and multi-phase measurements. It is demonstrated that incomplete metering of three-phase system quantities may lead to significant errors in the positive sequence state estimates for certain cases. Such cases may also lead to incorrect bad data detection and elimination, further deteriorating the quality of the state estimate. IEEE 30 bus test system is used to illustrate these cases.
非转置线路和不平衡负载对状态估计的影响
本文研究了由于通常假设母线负载/代完全平衡和传输线连续转置而在正序状态估计中引入的误差。为了验证相位坐标下的实际无误差解,首先建立了三相状态估计器。然后,使用关于单相和多相测量可用性的不同假设进行了几个测试。结果表明,在某些情况下,三相系统量的不完全计量可能导致正序状态估计的显著误差。这种情况还可能导致错误的坏数据检测和消除,进一步降低状态估计的质量。以ieee30总线测试系统为例进行了说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信