Accuracy of lead removal vs linear interpolation in non-invasive electrocardiographic imaging (ECGI)

L. Bear, M. Potse, J. Duchâteau, N. Zemzemi, Y. Coudière, R. Dubois
{"title":"Accuracy of lead removal vs linear interpolation in non-invasive electrocardiographic imaging (ECGI)","authors":"L. Bear, M. Potse, J. Duchâteau, N. Zemzemi, Y. Coudière, R. Dubois","doi":"10.1109/CIC.2015.7411067","DOIUrl":null,"url":null,"abstract":"This study examines the effect of missing body surface potentials on inverse solutions, and determines if linear interpolation can regain information lost. Using simulated and experimental data, electrograms (EGMs) were reconstructed after 1) removing and 2) interpolating `broken' signals. Results showed that torso potentials missing over the chest can reduce inverse reconstruction accuracy. Linear interpolation did not improve, and could further deteriorate reconstruction accuracy.","PeriodicalId":414802,"journal":{"name":"2015 Computing in Cardiology Conference (CinC)","volume":"135 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Computing in Cardiology Conference (CinC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.2015.7411067","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

This study examines the effect of missing body surface potentials on inverse solutions, and determines if linear interpolation can regain information lost. Using simulated and experimental data, electrograms (EGMs) were reconstructed after 1) removing and 2) interpolating `broken' signals. Results showed that torso potentials missing over the chest can reduce inverse reconstruction accuracy. Linear interpolation did not improve, and could further deteriorate reconstruction accuracy.
无创心电图成像(ECGI)中铅去除与线性插值的准确性
本研究考察了缺失的体表电位对反解的影响,并确定线性插值是否可以恢复丢失的信息。利用模拟和实验数据,在1)去除和2)插值“破碎”信号后重建了电图(EGMs)。结果表明,躯干电位在胸部缺失会降低反演的准确性。线性插值没有改善,而且会进一步降低重建精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信