{"title":"Simulation Models for Different Power System Faults","authors":"M. Srivastava, S. Goyal, A. Saraswat, G. Gangil","doi":"10.1109/ICADEE51157.2020.9368915","DOIUrl":null,"url":null,"abstract":"The power system behavior needs to be analyzed under all the possible different fault conditions which are the abnormal and undesirable conditions. Perhaps, these power system fault may lead to an unstable and unsecure power system operation. Therefore, a fast detection and consequent clearance of these faults is essential to resume normal operating condition in power system. In this paper, the short circuit responses (behaviors) of power system have been analyzed for various type of shunt-type faults (i.e. symmetrical and asymmetrical faults) as well as open-conductor faults using MATLAB Simulink platform. The study shows the significance of symmetrical and asymmetrical fault current investigations for the description of apparatus rating which must upkeep these currents.","PeriodicalId":202026,"journal":{"name":"2020 IEEE International Conference on Advances and Developments in Electrical and Electronics Engineering (ICADEE)","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on Advances and Developments in Electrical and Electronics Engineering (ICADEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICADEE51157.2020.9368915","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

The power system behavior needs to be analyzed under all the possible different fault conditions which are the abnormal and undesirable conditions. Perhaps, these power system fault may lead to an unstable and unsecure power system operation. Therefore, a fast detection and consequent clearance of these faults is essential to resume normal operating condition in power system. In this paper, the short circuit responses (behaviors) of power system have been analyzed for various type of shunt-type faults (i.e. symmetrical and asymmetrical faults) as well as open-conductor faults using MATLAB Simulink platform. The study shows the significance of symmetrical and asymmetrical fault current investigations for the description of apparatus rating which must upkeep these currents.
电力系统不同故障的仿真模型
需要对电力系统在各种可能的不同故障条件下的行为进行分析,这些故障条件是异常的和不期望的。这些电力系统故障可能会导致电力系统运行不稳定和不安全。因此,快速检测并排除这些故障对于恢复电力系统的正常运行至关重要。本文利用MATLAB Simulink平台,分析了电力系统在各种类型的并联型故障(即对称故障和不对称故障)以及开导线故障下的短路响应(行为)。研究表明,对称和不对称故障电流研究对于描述必须保持这些电流的设备额定值具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信