Effect of frequency on XLPE cable insulation at high electric field

S. Bamji, A. Bulinski, L. Cissé, K. Tohyama
{"title":"Effect of frequency on XLPE cable insulation at high electric field","authors":"S. Bamji, A. Bulinski, L. Cissé, K. Tohyama","doi":"10.1109/CEIDP.2001.963513","DOIUrl":null,"url":null,"abstract":"Electroluminescence (EL), the emission of light in dielectrics subjected to high electric stress, is a very sensitive technique to detect space charge injection and the very early stages of insulation degradation. In this paper the EL technique is employed to determine the effect of frequency in the range of 5 to 600 Hz on unaged and aged crosslinked polyethylene (XLPE) insulation of underground high voltage cables. The number of EL pulses emitted from XLPE and the area of the space charge region simultaneously obtained by the PMT and CCD camera are studied as the frequency of the ac voltage is varied between 5 and 600 Hz. The implications of the frequency range on diagnostic tests performed on the polymeric insulation of underground power cables is discussed.","PeriodicalId":112180,"journal":{"name":"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.01CH37225)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2001.963513","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Electroluminescence (EL), the emission of light in dielectrics subjected to high electric stress, is a very sensitive technique to detect space charge injection and the very early stages of insulation degradation. In this paper the EL technique is employed to determine the effect of frequency in the range of 5 to 600 Hz on unaged and aged crosslinked polyethylene (XLPE) insulation of underground high voltage cables. The number of EL pulses emitted from XLPE and the area of the space charge region simultaneously obtained by the PMT and CCD camera are studied as the frequency of the ac voltage is varied between 5 and 600 Hz. The implications of the frequency range on diagnostic tests performed on the polymeric insulation of underground power cables is discussed.
高电场下频率对交联聚乙烯电缆绝缘的影响
电致发光(EL)是一种在高电应力下的介质中发射的光,是一种非常敏感的技术,可以检测空间电荷注入和绝缘退化的早期阶段。本文采用EL技术测定了5 ~ 600hz频率对地下高压电缆未老化和老化交联聚乙烯(XLPE)绝缘的影响。研究了交流电压频率在5 ~ 600hz范围内变化时,PMT和CCD相机同时获得的XLPE发射的EL脉冲数和空间电荷区面积。讨论了频率范围对地下电力电缆聚合物绝缘诊断试验的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信