A comparision and analysis of dynamic hip screw v/s multiple cannulated cancellous screws for neck femur fractures in young Indian population

Dr. Prabhav Tijoriwala, D. Patel, Dr. Sunny Patel, Dr. Ekta Mehta, Dr. Dharmesh Machhar, Dr. Janak Rathod
{"title":"A comparision and analysis of dynamic hip screw v/s multiple cannulated cancellous screws for neck femur fractures in young Indian population","authors":"Dr. Prabhav Tijoriwala, D. Patel, Dr. Sunny Patel, Dr. Ekta Mehta, Dr. Dharmesh Machhar, Dr. Janak Rathod","doi":"10.33545/orthor.2021.v5.i4a.328","DOIUrl":null,"url":null,"abstract":"Background: Femoral neck fractures are one of the problems in clinical treatment. The prognosis is uncertain. Currently, no internal fixation method is superior to other internal fixation methods in the treatment of femoral neck fractures. Therefore, the internal fixation system needs to be further explored. The aim of this study was to compare clinical outcomes of femoral neck dynamic Hip screw system and multiple cannulated compression screws in the treatment of femoral neck fractures. Methods: This randomized control trial was conducted in the Department of Orthopedics, SURAT Municipal Institute of Medical Science, Surat. Results: 6 months Post operatively Harris Hip score evaluations clearly state DHS as a superior implant to cancellous screws. Also, there was 1 fixation failure in DHS group whereas there were 3 fixation failure in Cannulated screw groups. The surgery duration, radiation time and blood loss were significantly low with cannulated cancellous screws. Conclusion: The results of present study support the hypothesis that DHS is a better implant than CC screws in management of fracture neck femur in young adults in pauwels type II and III in terms of functional outcome but complication rate does not depend on the implant selection, however a longer follow up will consolidate these results. Although the surgery duration, radiation time, blood loss and infection rate is more in DHS. It gives a better result than CC screws based on radiological union and functional status of the patients.","PeriodicalId":151163,"journal":{"name":"National Journal of Clinical Orthopaedics","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"National Journal of Clinical Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33545/orthor.2021.v5.i4a.328","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Femoral neck fractures are one of the problems in clinical treatment. The prognosis is uncertain. Currently, no internal fixation method is superior to other internal fixation methods in the treatment of femoral neck fractures. Therefore, the internal fixation system needs to be further explored. The aim of this study was to compare clinical outcomes of femoral neck dynamic Hip screw system and multiple cannulated compression screws in the treatment of femoral neck fractures. Methods: This randomized control trial was conducted in the Department of Orthopedics, SURAT Municipal Institute of Medical Science, Surat. Results: 6 months Post operatively Harris Hip score evaluations clearly state DHS as a superior implant to cancellous screws. Also, there was 1 fixation failure in DHS group whereas there were 3 fixation failure in Cannulated screw groups. The surgery duration, radiation time and blood loss were significantly low with cannulated cancellous screws. Conclusion: The results of present study support the hypothesis that DHS is a better implant than CC screws in management of fracture neck femur in young adults in pauwels type II and III in terms of functional outcome but complication rate does not depend on the implant selection, however a longer follow up will consolidate these results. Although the surgery duration, radiation time, blood loss and infection rate is more in DHS. It gives a better result than CC screws based on radiological union and functional status of the patients.
动态髋螺钉与多空腔松质螺钉治疗印度青年股骨颈骨折的比较分析
背景:股骨颈骨折是临床治疗的难题之一。预后不确定。目前,在股骨颈骨折的治疗中,没有一种内固定方法优于其他内固定方法。因此,内固定系统需要进一步探索。本研究的目的是比较股骨颈动力髋关节螺钉系统和多个空心加压螺钉治疗股骨颈骨折的临床效果。方法:本随机对照试验在苏拉特市医学科学研究所骨科进行。结果:术后6个月Harris髋关节评分评估明确表明DHS是优于松质螺钉的植入物。DHS组有1例固定失败,空心螺钉组有3例。空心松质螺钉的手术时间、放疗时间和出血量均明显较低。结论:本研究结果支持这样的假设:DHS在治疗II型和III型年轻成人的股骨颈骨折中比CC螺钉在功能预后方面更好,但并发症发生率与植入物的选择无关,但更长时间的随访将巩固这些结果。虽然手术时间、放疗时间、出血量和感染率在DHS中较高。根据患者的放射愈合和功能状况,其效果优于CC螺钉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信