A prospective randomized comparative study between Macintosh and GlideScope in adult patients undergoing cardiac surgery

R. Soliman, M. Mofeed, Osama Alamoudy, A. Farouk
{"title":"A prospective randomized comparative study between Macintosh and GlideScope in adult patients undergoing cardiac surgery","authors":"R. Soliman, M. Mofeed, Osama Alamoudy, A. Farouk","doi":"10.4103/1687-9090.160326","DOIUrl":null,"url":null,"abstract":"Context The GlideScope laryngoscope is a new device for intubation that provides an improved view of the larynx. Aim The aim of the study was to compare the hemodynamic effect of Macintosh laryngoscope with GlideScope during intubation in adult cardiac surgery. Setting and design This was a prospective, randomized, comparative study conducted in Madinah Cardiac Center, Saudi Arabia. Materials and methods The study included 100 patients classified into two groups (n = 50), The patients were intubated either by Macintosh laryngoscope or by GlideScope. The following parameters were monitored: heart rate, mean arterial blood pressure, catecholamine level, intubation time, number of intubation trials, and the complications. Statistical analysis used Data were statistically described in terms of mean ΁ SD or frequencies. Measurements and main results The intubation time was longer in GlideScope than in Macintosh (P < 0.001), and the number of intubation trials was higher in GlideScope than in Macintosh (P < 0.001). The heart rate increased significantly in patients of the GlideScope group compared with the Macintosh group at first minute (P < 0.001), third minute (P < 0.001), and at fifth minute (P = 0.034). The mean arterial blood pressure increased significantly in patients of the GlideScope group compared with the Macintosh group at first minute (P < 0.001), third minute (P = 0.003), and at fifth minute (P = 0.029). The epinephrine level was higher with GlideScope at first and fifth minute (P = 0.032 and 0.036, respectively). The norepinephrine was higher in the GlideScope group at first and fifth minute (P = 0.043 and 0.033, respectively). The incidence of oral trauma and bleeding was higher with GlideScope than Macintosh (P = 0.003). Conclusion The intubation by GlideScope is associated with increased heart rate, blood pressure, catecholamine level, number of intubation trials, and oral complications compared with Macintosh laryngoscope.","PeriodicalId":289218,"journal":{"name":"The Egyptian Journal of Cardiothoracic Anesthesia","volume":"121 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Egyptian Journal of Cardiothoracic Anesthesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/1687-9090.160326","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

Context The GlideScope laryngoscope is a new device for intubation that provides an improved view of the larynx. Aim The aim of the study was to compare the hemodynamic effect of Macintosh laryngoscope with GlideScope during intubation in adult cardiac surgery. Setting and design This was a prospective, randomized, comparative study conducted in Madinah Cardiac Center, Saudi Arabia. Materials and methods The study included 100 patients classified into two groups (n = 50), The patients were intubated either by Macintosh laryngoscope or by GlideScope. The following parameters were monitored: heart rate, mean arterial blood pressure, catecholamine level, intubation time, number of intubation trials, and the complications. Statistical analysis used Data were statistically described in terms of mean ΁ SD or frequencies. Measurements and main results The intubation time was longer in GlideScope than in Macintosh (P < 0.001), and the number of intubation trials was higher in GlideScope than in Macintosh (P < 0.001). The heart rate increased significantly in patients of the GlideScope group compared with the Macintosh group at first minute (P < 0.001), third minute (P < 0.001), and at fifth minute (P = 0.034). The mean arterial blood pressure increased significantly in patients of the GlideScope group compared with the Macintosh group at first minute (P < 0.001), third minute (P = 0.003), and at fifth minute (P = 0.029). The epinephrine level was higher with GlideScope at first and fifth minute (P = 0.032 and 0.036, respectively). The norepinephrine was higher in the GlideScope group at first and fifth minute (P = 0.043 and 0.033, respectively). The incidence of oral trauma and bleeding was higher with GlideScope than Macintosh (P = 0.003). Conclusion The intubation by GlideScope is associated with increased heart rate, blood pressure, catecholamine level, number of intubation trials, and oral complications compared with Macintosh laryngoscope.
Macintosh和GlideScope在成人心脏手术患者中的前瞻性随机比较研究
GlideScope喉镜是一种新型的气管插管设备,提供了一个更好的喉部视图。目的比较麦金塔喉镜与滑翔镜在成人心脏手术插管时的血流动力学效果。背景和设计这是一项在沙特阿拉伯麦地那心脏中心进行的前瞻性、随机、比较研究。材料与方法将100例患者分为两组(n = 50),分别采用Macintosh喉镜和GlideScope进行插管。监测心率、平均动脉血压、儿茶酚胺水平、插管时间、插管次数、并发症。数据以平均标准差或频率进行统计描述。GlideScope插管时间比Macintosh长(P < 0.001),插管试验次数比Macintosh多(P < 0.001)。与Macintosh组相比,GlideScope组患者的心率在第1分钟(P < 0.001)、第3分钟(P < 0.001)和第5分钟(P = 0.034)显著增加。与Macintosh组相比,GlideScope组患者的平均动脉血压在第1分钟(P < 0.001)、第3分钟(P = 0.003)和第5分钟(P = 0.029)显著升高。GlideScope在第1分钟和第5分钟肾上腺素水平较高(P分别为0.032和0.036)。GlideScope组去甲肾上腺素在第1分钟和第5分钟较高(P分别为0.043和0.033)。GlideScope的口腔外伤和出血发生率高于Macintosh (P = 0.003)。结论与Macintosh喉镜相比,GlideScope插管可增加心率、血压、儿茶酚胺水平、插管次数和口腔并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信