A novel out-of-step detection algorithm using angle of power signal

R. Dubey, S. Samantaray, B. Babu, S. N. Kumar
{"title":"A novel out-of-step detection algorithm using angle of power signal","authors":"R. Dubey, S. Samantaray, B. Babu, S. N. Kumar","doi":"10.1109/ICPES.2011.6156631","DOIUrl":null,"url":null,"abstract":"The electric power system maintains a dynamic and delicate balance between generation and load in normal operation condition. A disturbance, such as a sudden change of load, a power system fault, or a trip of a large generation unit, may break the balance, cause the oscillations among the generator rotor angles and force the generators to adjust to a new operating condition. The adjustment will not happen instantaneously due to the inertia of the generator prime movers. The oscillation will cause either stable and/or unstable power swings. During a power swing, the impedance trajectory seen by a distance relay may enter the fault detection zones and cause unwanted relay operation. Distinguishing stable and unstable power swing is one of the challenging tasks. This paper presents a wavelet based energy function for distinguishing stable and unstable power swing using Wavelet based Power Angle criteria.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156631","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

The electric power system maintains a dynamic and delicate balance between generation and load in normal operation condition. A disturbance, such as a sudden change of load, a power system fault, or a trip of a large generation unit, may break the balance, cause the oscillations among the generator rotor angles and force the generators to adjust to a new operating condition. The adjustment will not happen instantaneously due to the inertia of the generator prime movers. The oscillation will cause either stable and/or unstable power swings. During a power swing, the impedance trajectory seen by a distance relay may enter the fault detection zones and cause unwanted relay operation. Distinguishing stable and unstable power swing is one of the challenging tasks. This paper presents a wavelet based energy function for distinguishing stable and unstable power swing using Wavelet based Power Angle criteria.
一种新的基于功率信号角度的失步检测算法
电力系统在正常运行状态下,发电量与负荷之间保持着动态而微妙的平衡。负荷的突然变化、电力系统的故障或大型发电机组的跳闸等扰动都可能打破平衡,引起发电机转子角度之间的振荡,迫使发电机调整到新的运行状态。由于发电机原动机的惯性,调整不会立即发生。振荡将导致稳定和/或不稳定的功率摆动。在功率摆动期间,距离继电器看到的阻抗轨迹可能进入故障检测区域,并导致不必要的继电器操作。区分稳定和不稳定的权力摆动是一项具有挑战性的任务。利用小波功率角判据,提出了一种基于小波能量函数的稳定与不稳定功率摆的判别方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信