{"title":"Energetic Assessment of an Electronic and a Thermostatic Expansion Valve for a Variable Capacity Compressor","authors":"O. Ekren","doi":"10.15377/2409-5826.2019.06.6","DOIUrl":null,"url":null,"abstract":"In this study, a chiller system with an electronic expansion valve (EEV) and a thermostatic expansion valve (TXV) were compared from an energy saving view under variable and fixed speed compressor. The experimental chiller system under study has a variable speed scroll compressor, EEV and TXV, air cooled condenser and auxiliary equipments. The R134a was used in the compressor as a refrigerant. Although in variable speed chiller systems usually EEVs are used, in this study a TXV was also used to compare its performance. The results of the experimental studies show that the chiller system with EEV has 30% lower superheat value and 6% lower power consumption than the chiller system with TXV under variable speed operation. From the fixed speed compressor view, the chiller system with TXV performs 1.7% lower superheat value than the chiller system with EEV and, the chiller system with EEV has 8.5% higher compressor power consumption than TXV.","PeriodicalId":244913,"journal":{"name":"Journal of Advanced Thermal Science Research","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Thermal Science Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15377/2409-5826.2019.06.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, a chiller system with an electronic expansion valve (EEV) and a thermostatic expansion valve (TXV) were compared from an energy saving view under variable and fixed speed compressor. The experimental chiller system under study has a variable speed scroll compressor, EEV and TXV, air cooled condenser and auxiliary equipments. The R134a was used in the compressor as a refrigerant. Although in variable speed chiller systems usually EEVs are used, in this study a TXV was also used to compare its performance. The results of the experimental studies show that the chiller system with EEV has 30% lower superheat value and 6% lower power consumption than the chiller system with TXV under variable speed operation. From the fixed speed compressor view, the chiller system with TXV performs 1.7% lower superheat value than the chiller system with EEV and, the chiller system with EEV has 8.5% higher compressor power consumption than TXV.