A Portable Spectrophotometer-Based Breathalyzer for Point-of-Care Testing of Diabetic Patients

Nicole M. Banach, M. Rust, R. Priefer
{"title":"A Portable Spectrophotometer-Based Breathalyzer for Point-of-Care Testing of Diabetic Patients","authors":"Nicole M. Banach, M. Rust, R. Priefer","doi":"10.1109/NEBEC.2013.44","DOIUrl":null,"url":null,"abstract":"Diabetes Mellitus is a metabolic disorder characterized by the lack of sufficient insulin. This disease has become a national epidemic in the United States, and therapy non-adherence has become one of the largest precursors leading to diabetic sequelae such as diabetic ketoacidosis. A potential source of patient therapy negligence is the discomfort associated with the finger prick method of glucose monitoring. As a result, a less invasive method to monitor diabetes is sought. This paper describes a portable breathalyzer that is being developed to monitor acetone in the breath of a diabetic patient. The proposed design aims to eliminate the finger prick through a simplified approach for monitoring acetone levels in correlation to elevated glucose levels, thus determining the onset of diabetic ketoacidosis.","PeriodicalId":153112,"journal":{"name":"2013 39th Annual Northeast Bioengineering Conference","volume":"155 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 39th Annual Northeast Bioengineering Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NEBEC.2013.44","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Diabetes Mellitus is a metabolic disorder characterized by the lack of sufficient insulin. This disease has become a national epidemic in the United States, and therapy non-adherence has become one of the largest precursors leading to diabetic sequelae such as diabetic ketoacidosis. A potential source of patient therapy negligence is the discomfort associated with the finger prick method of glucose monitoring. As a result, a less invasive method to monitor diabetes is sought. This paper describes a portable breathalyzer that is being developed to monitor acetone in the breath of a diabetic patient. The proposed design aims to eliminate the finger prick through a simplified approach for monitoring acetone levels in correlation to elevated glucose levels, thus determining the onset of diabetic ketoacidosis.
用于糖尿病患者即时检测的便携式分光光度计呼气分析仪
糖尿病是一种代谢紊乱,其特征是缺乏足够的胰岛素。此病在美国已成为一种全国性的流行病,治疗不依从已成为导致糖尿病酮症酸中毒等糖尿病后遗症的最大前兆之一。患者治疗疏忽的一个潜在来源是与手指刺破血糖监测方法相关的不适。因此,人们寻求一种侵入性较小的方法来监测糖尿病。本文介绍了一种用于监测糖尿病患者呼吸中的丙酮的便携式呼气分析仪。该设计旨在通过一种简单的方法来监测丙酮水平与葡萄糖水平升高的关系,从而确定糖尿病酮症酸中毒的发生,从而消除手指刺痛。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信