Reliability investigation of SiC bipolar device module in long time inverter operation

A. Tanaka, S. Ogata, T. Izumi, K. Nakayama, T. Hayashi, Y. Miyanagi, K. Asano
{"title":"Reliability investigation of SiC bipolar device module in long time inverter operation","authors":"A. Tanaka, S. Ogata, T. Izumi, K. Nakayama, T. Hayashi, Y. Miyanagi, K. Asano","doi":"10.1109/ISPSD.2012.6229066","DOIUrl":null,"url":null,"abstract":"The reliability of SiC bipolar device modules consisting of SiC commutated gate turn-off thyristors and SiC pin diodes fabricated on a 4° off-cut SiC substrate is investigated. According to three-phase inverter operation using a Back to Back system at DC bus voltage of 2 kV and effective output power of approximately 120 kW, the SiC module could achieve the world's first successful inverter operation lasting more than 1000 hours, thereby verifying its reliability in long time inverter operation.","PeriodicalId":371298,"journal":{"name":"2012 24th International Symposium on Power Semiconductor Devices and ICs","volume":"227 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 24th International Symposium on Power Semiconductor Devices and ICs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPSD.2012.6229066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

The reliability of SiC bipolar device modules consisting of SiC commutated gate turn-off thyristors and SiC pin diodes fabricated on a 4° off-cut SiC substrate is investigated. According to three-phase inverter operation using a Back to Back system at DC bus voltage of 2 kV and effective output power of approximately 120 kW, the SiC module could achieve the world's first successful inverter operation lasting more than 1000 hours, thereby verifying its reliability in long time inverter operation.
SiC双极器件模块在逆变器长时间运行中的可靠性研究
研究了在4°截止SiC衬底上由SiC整流栅关断晶闸管和SiC引脚二极管组成的SiC双极器件模块的可靠性。根据直流母线电压为2 kV,有效输出功率约为120 kW的背靠背三相逆变器运行情况,SiC模块在世界上首次成功实现了逆变器持续运行1000小时以上,验证了其在逆变器长时间运行中的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信