The change of DC parameters of 35kV ZnO arrester under continuous single heavy lightning strike

Yutang Ma, Fangrong Zhou, Hao Geng, Wei Chen, Lin Huang
{"title":"The change of DC parameters of 35kV ZnO arrester under continuous single heavy lightning strike","authors":"Yutang Ma, Fangrong Zhou, Hao Geng, Wei Chen, Lin Huang","doi":"10.1109/icsai53574.2021.9664203","DOIUrl":null,"url":null,"abstract":"As an important part of power system, zinc oxide arrester plays an indispensable role in limiting the over-voltage and lightning protection of power system. Frequent lightning strikes in nature will affect the performance of ZnO arresters, and thus affect the safe and stable operation of the whole power system. Therefore, it is important to study the DC parameters of ZnO arresters under lightning stroke to judge the aging state of zinc oxide arrester. This paper establishes a continuous single heavy lightning test platform, simulates the state of zinc oxide arrester subjected to continuous lightning stroke, and obtains the DC parameter change of 35kV zinc oxide arrester under the influence of continuous lightning stroke. The results show that after 50 continuous single heavy lightning strikes, the leakage current of 35kV zinc oxide arrester increases by 70% and U1mA decreases by 7.72%. It is concluded that the arrester is aging seriously and the insulation state is getting worse and worse.","PeriodicalId":131284,"journal":{"name":"2021 7th International Conference on Systems and Informatics (ICSAI)","volume":"38 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 7th International Conference on Systems and Informatics (ICSAI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/icsai53574.2021.9664203","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

As an important part of power system, zinc oxide arrester plays an indispensable role in limiting the over-voltage and lightning protection of power system. Frequent lightning strikes in nature will affect the performance of ZnO arresters, and thus affect the safe and stable operation of the whole power system. Therefore, it is important to study the DC parameters of ZnO arresters under lightning stroke to judge the aging state of zinc oxide arrester. This paper establishes a continuous single heavy lightning test platform, simulates the state of zinc oxide arrester subjected to continuous lightning stroke, and obtains the DC parameter change of 35kV zinc oxide arrester under the influence of continuous lightning stroke. The results show that after 50 continuous single heavy lightning strikes, the leakage current of 35kV zinc oxide arrester increases by 70% and U1mA decreases by 7.72%. It is concluded that the arrester is aging seriously and the insulation state is getting worse and worse.
连续单次强雷击下35kV ZnO避雷器直流参数的变化
氧化锌避雷器作为电力系统的重要组成部分,在电力系统的限过电压和防雷保护中起着不可缺少的作用。自然界频繁的雷击会影响ZnO避雷器的性能,从而影响整个电力系统的安全稳定运行。因此,研究雷电作用下氧化锌避雷器的直流参数对判断氧化锌避雷器的老化状态具有重要意义。本文建立了连续单次重雷试验平台,模拟氧化锌避雷器在连续雷击下的状态,得到35kV氧化锌避雷器在连续雷击影响下的直流参数变化。结果表明:连续50次单次强雷击后,35kV氧化锌避雷器的漏电流增大70%,U1mA减小7.72%;结果表明,避雷器老化严重,绝缘状态越来越差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信