Damping Power System Oscillations in Single-Machine Infinite-Bus Power System Using a STATCOM

G. Shahgholian, Pegah Shafaghi, Sepehr Moalem, M. Mahdavian
{"title":"Damping Power System Oscillations in Single-Machine Infinite-Bus Power System Using a STATCOM","authors":"G. Shahgholian, Pegah Shafaghi, Sepehr Moalem, M. Mahdavian","doi":"10.1109/ICCEE.2009.30","DOIUrl":null,"url":null,"abstract":"The aim of this paper is dynamic modeling and analysis of STATCOM for a single-machine infinite-bus (SMIB) power system. Also the study the applicability of PID type in dynamic performance enhancement with eigenvalue analysis is shown. Non-linear and linear models of a single machine have been derived. The STATCOM is modeled as a reactive current source with a time delay. A comparative study for two control inputs, one in the speed loop and the other in the voltage loop, for STATCOM controller using eigenvalues analysis is shown.","PeriodicalId":343870,"journal":{"name":"2009 Second International Conference on Computer and Electrical Engineering","volume":"1049 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 Second International Conference on Computer and Electrical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCEE.2009.30","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

The aim of this paper is dynamic modeling and analysis of STATCOM for a single-machine infinite-bus (SMIB) power system. Also the study the applicability of PID type in dynamic performance enhancement with eigenvalue analysis is shown. Non-linear and linear models of a single machine have been derived. The STATCOM is modeled as a reactive current source with a time delay. A comparative study for two control inputs, one in the speed loop and the other in the voltage loop, for STATCOM controller using eigenvalues analysis is shown.
用STATCOM抑制单机无限母线电力系统的振荡
本文的目的是对单机无限母线(SMIB)电力系统的STATCOM进行动态建模和分析。研究了PID型在特征值分析动态性能增强中的适用性。推导了单台机器的非线性和线性模型。STATCOM被建模为具有时间延迟的无功电流源。采用特征值分析方法对速度环和电压环两个控制输入进行了对比研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信