Electro-inductive Wave Transmission Line based Microfluidic Microwave Sensor

M. Gil, P. Vélez, F. Aznar-Ballesta, A. Mesegar-Ruiz, Jonatan Muñoz-Enano, Marcos Duque, F. Martín
{"title":"Electro-inductive Wave Transmission Line based Microfluidic Microwave Sensor","authors":"M. Gil, P. Vélez, F. Aznar-Ballesta, A. Mesegar-Ruiz, Jonatan Muñoz-Enano, Marcos Duque, F. Martín","doi":"10.1109/IMBIoC47321.2020.9384903","DOIUrl":null,"url":null,"abstract":"We propose the use of electro-inductive wave (EIW) transmission lines based on complementary split-ring resonators (CSRR) to implement a differential-mode microwave sensor for biological fluid sensing purposes. Differential-mode operation is achieved by comparing the response of the device loaded with a reference (REF) sample to the one of the sensor loaded with a sample under test (SUT). By this means, any alteration or difference in the SUT as compared to the REF sample (seen as an asymmetry) can be detected. The designed and fabricated device has been validated by considering ethanol and glucose solutions in pure deionized (DI) water. The main relevant aspect of the proposed sensor is the high sensitivity and resolution. Thus, this device is especially useful for the characterization of solute content in very diluted solutions.","PeriodicalId":297049,"journal":{"name":"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","volume":"303 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-12-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE MTT-S International Microwave Biomedical Conference (IMBioC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMBIoC47321.2020.9384903","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We propose the use of electro-inductive wave (EIW) transmission lines based on complementary split-ring resonators (CSRR) to implement a differential-mode microwave sensor for biological fluid sensing purposes. Differential-mode operation is achieved by comparing the response of the device loaded with a reference (REF) sample to the one of the sensor loaded with a sample under test (SUT). By this means, any alteration or difference in the SUT as compared to the REF sample (seen as an asymmetry) can be detected. The designed and fabricated device has been validated by considering ethanol and glucose solutions in pure deionized (DI) water. The main relevant aspect of the proposed sensor is the high sensitivity and resolution. Thus, this device is especially useful for the characterization of solute content in very diluted solutions.
基于电感性波传输线的微流控微波传感器
我们建议使用基于互补劈环谐振器(CSRR)的电感性波(EIW)传输线来实现用于生物流体传感目的的差模微波传感器。差模操作是通过比较加载参考样品(REF)的设备的响应与加载待测样品(SUT)的传感器的响应来实现的。通过这种方法,可以检测到SUT与REF样品(视为不对称)相比的任何改变或差异。通过考虑乙醇和葡萄糖溶液在纯去离子水中的作用,对所设计和制造的装置进行了验证。该传感器的主要相关方面是高灵敏度和高分辨率。因此,该装置特别适用于非常稀释溶液中溶质含量的表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信