{"title":"High Voltage Breakdown Performance and Circuit Isolation Capability of Vacuum Interrupters","authors":"E. Taylor, P. Slade","doi":"10.1109/DEIV.2006.357269","DOIUrl":null,"url":null,"abstract":"High voltage breakdown experiments determined the ability of vacuum interrupters to provide adequate circuit isolation in the open position. The vacuum interrupters were rated for a 38kV system voltage, and contained either Cu-W (10 wt.%) or Cu-Cr contacts. Sample interrupters were voltage conditioned with a peak AC voltage of 160kV. The statistical distribution of the BIL breakdown voltage for 3 and 5 mm contact gaps were determined using the up-down method for newly conditioned contacts. A three-parameter Weibull distribution fit the breakdown data, implying the existence of a threshold value below which no breakdowns occurs. These results are discussed in terms of the high voltage capabilities of Cu-W contacts and with respect of the peak open-circuit voltages for typical 38 kV applications. The vacuum breakdown behavior is also compared to the breakdown in SF6","PeriodicalId":369861,"journal":{"name":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","volume":"89 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2006 International Symposium on Discharges and Electrical Insulation in Vacuum","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DEIV.2006.357269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
High voltage breakdown experiments determined the ability of vacuum interrupters to provide adequate circuit isolation in the open position. The vacuum interrupters were rated for a 38kV system voltage, and contained either Cu-W (10 wt.%) or Cu-Cr contacts. Sample interrupters were voltage conditioned with a peak AC voltage of 160kV. The statistical distribution of the BIL breakdown voltage for 3 and 5 mm contact gaps were determined using the up-down method for newly conditioned contacts. A three-parameter Weibull distribution fit the breakdown data, implying the existence of a threshold value below which no breakdowns occurs. These results are discussed in terms of the high voltage capabilities of Cu-W contacts and with respect of the peak open-circuit voltages for typical 38 kV applications. The vacuum breakdown behavior is also compared to the breakdown in SF6