Assessment of High Voltage Power Transformer Aging Condition Based on Health Index Value Considering Its Apparent and Actual Age

Winanda Riga Tamma, Rahman Azis Prasojo, S. Suwarno
{"title":"Assessment of High Voltage Power Transformer Aging Condition Based on Health Index Value Considering Its Apparent and Actual Age","authors":"Winanda Riga Tamma, Rahman Azis Prasojo, S. Suwarno","doi":"10.1109/ICITEE49829.2020.9271778","DOIUrl":null,"url":null,"abstract":"Power transformer takes an important place in the electrical delivery system. This equipment has to maintain its reliability and performance in order to provide good electricity. Power transformer is expected to be operated around 20-40 years. However, sometimes power transformer may fail before it should be. This event may be due to accelerated aging experienced by the equipment. This paper proposes a method to identify the 150 kV transformer aging condition by considering its apparent age based on its health index value. From the health index analysis of 130 power transformers included in the regression model, a linear graph which represent the health index decrease of the population were obtained, with correlation coefficient of R2 0.713. The proposed graph then be used to calculate the apparent age and aging condition of the transformer. This method could help the asset manager to take suitable action to maintain the transformer reliability and performance.","PeriodicalId":245013,"journal":{"name":"2020 12th International Conference on Information Technology and Electrical Engineering (ICITEE)","volume":"33 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 12th International Conference on Information Technology and Electrical Engineering (ICITEE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICITEE49829.2020.9271778","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Power transformer takes an important place in the electrical delivery system. This equipment has to maintain its reliability and performance in order to provide good electricity. Power transformer is expected to be operated around 20-40 years. However, sometimes power transformer may fail before it should be. This event may be due to accelerated aging experienced by the equipment. This paper proposes a method to identify the 150 kV transformer aging condition by considering its apparent age based on its health index value. From the health index analysis of 130 power transformers included in the regression model, a linear graph which represent the health index decrease of the population were obtained, with correlation coefficient of R2 0.713. The proposed graph then be used to calculate the apparent age and aging condition of the transformer. This method could help the asset manager to take suitable action to maintain the transformer reliability and performance.
考虑视龄和实际龄的高压电力变压器健康指数值老化状况评估
电力变压器在电力输送系统中占有重要地位。为了提供良好的电力,该设备必须保持其可靠性和性能。电力变压器预计运行20-40年左右。然而,有时电力变压器可能在它应该出现之前就出现故障。此事件可能是由于设备加速老化造成的。提出了一种基于健康指标值考虑变压器表观年龄的150 kV变压器老化状况识别方法。通过对纳入回归模型的130台电力变压器的健康指数分析,得到了总体健康指数下降的线性图,相关系数R2为0.713。然后用该图计算变压器的表观寿命和老化情况。该方法可以帮助资产管理者采取适当的措施来维护变压器的可靠性和性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信