Smallest dead volume microvalves for integrated chemical analyzing systems

S. Shoji, B. van der Schoot, N. D. de Rooij, M. Esashi
{"title":"Smallest dead volume microvalves for integrated chemical analyzing systems","authors":"S. Shoji, B. van der Schoot, N. D. de Rooij, M. Esashi","doi":"10.1109/SENSOR.1991.149077","DOIUrl":null,"url":null,"abstract":"Normally open, normally closed, and three-way microvalves were developed. These microvalves had a simple structure and small dead volume on the order of tens of nl. Each microvalve was driven by a stack-type piezo-actuator and the controllable flow range is from 1 mu l/min to tens of mu l/min. These valves are useful for constructing integrated chemical analyzing systems.<<ETX>>","PeriodicalId":273871,"journal":{"name":"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers","volume":"110 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"48","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.1991.149077","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 48

Abstract

Normally open, normally closed, and three-way microvalves were developed. These microvalves had a simple structure and small dead volume on the order of tens of nl. Each microvalve was driven by a stack-type piezo-actuator and the controllable flow range is from 1 mu l/min to tens of mu l/min. These valves are useful for constructing integrated chemical analyzing systems.<>
用于集成化学分析系统的最小死体积微阀
常开、常闭、三通微阀相继问世。这些微阀结构简单,死体积小,约为数十个nl。每个微阀由堆叠式压电执行器驱动,可控流量范围为1 μ l/min至数十μ l/min。这些阀门对于构建综合化学分析系统是有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信