{"title":"Prevention of Power System Blackouts Using Windowed-Prony Method","authors":"Kasimala Venkatanagaraju, M. Biswal","doi":"10.1109/PIICON49524.2020.9112951","DOIUrl":null,"url":null,"abstract":"Zone-3 unit of conventional distance relay is vulnerable to voltage instability and load-encroachment which are known as system stress conditions. For such conditions, the impedance trajectory encroaches zone-3 reach. Based on the setting parameters of the relay, it is identified as a fault and relay may maloperate. However, the relay may maloperate for any three-phase fault during such stress events as the change in system parameters are identical for both the conditions. Zone-3 maloperation is the root cause behind 2012 Indian blackout. So, it is necessary to introduce a supporting algorithm to avoid relay maloperations and to curtail the occurrence of any blackout. This paper introduces windowed-Prony method to detect and discriminate fault from system stress conditions. This method will be activated when the impedance trajectory enters the setting zone-3 region. It is used to approximate the input signal and to estimate the error existing between actual and approximated signals. The squared error is considered as a fault detection index (FDI). The performance of this method is tested on IEEE 39 bus test system.","PeriodicalId":422853,"journal":{"name":"2020 IEEE 9th Power India International Conference (PIICON)","volume":"326 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE 9th Power India International Conference (PIICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIICON49524.2020.9112951","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Zone-3 unit of conventional distance relay is vulnerable to voltage instability and load-encroachment which are known as system stress conditions. For such conditions, the impedance trajectory encroaches zone-3 reach. Based on the setting parameters of the relay, it is identified as a fault and relay may maloperate. However, the relay may maloperate for any three-phase fault during such stress events as the change in system parameters are identical for both the conditions. Zone-3 maloperation is the root cause behind 2012 Indian blackout. So, it is necessary to introduce a supporting algorithm to avoid relay maloperations and to curtail the occurrence of any blackout. This paper introduces windowed-Prony method to detect and discriminate fault from system stress conditions. This method will be activated when the impedance trajectory enters the setting zone-3 region. It is used to approximate the input signal and to estimate the error existing between actual and approximated signals. The squared error is considered as a fault detection index (FDI). The performance of this method is tested on IEEE 39 bus test system.