{"title":"A sub-10nA DC-balanced adaptive stimulator IC with multimodal sensor for compact electro-acupuncture system","authors":"Kiseok Song, Hyungwoo Lee, Sunjoo Hong, Hyunwoo Cho, H. Yoo","doi":"10.1109/ISSCC.2012.6177021","DOIUrl":null,"url":null,"abstract":"Electro-acupuncture (EA), a combination of acupuncture and electrical stimulation, has been widely used for its effectiveness in pain relief since the 1970s [1] and later for treatment of various diseases such as depression, addiction, and gastrointestinal disorders [2], and non-medical applications including obesity treatment [3]. For stimulation, most EA systems use a pair of needles with long, thick wires connected to an external power supply to form a closed current loop. The thin (φ=2mm) needle may suffer from the inconvenient and unstable connection to the thick wire and if there are many needles, it is difficult to supply power to all needles [4]. Recently, a wirelessly-powered EA system was proposed in [4] to remove the wire connections for convenient treatment, but its wireless power harvesting generated only 8μW which is not enough for various applications [1-3]. Most EA systems use bi-phase stimulation to reduce tissue damage, electrolysis, and electrolytic degradation [5]. However, the high-precision balancing of a bi-phase current pulse is difficult to achieve because the required offset, <;10nA [6], is only on the order of 10<;sup>;-5<;/sup>; of the stimulation current level, ~1mA. Furthermore, none of the previous EA systems have any feedback mechanism to enable adaptive stimulation by showing the real-time status of the EA stimulation to the patient.","PeriodicalId":255282,"journal":{"name":"2012 IEEE International Solid-State Circuits Conference","volume":"618 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-04-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE International Solid-State Circuits Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCC.2012.6177021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Electro-acupuncture (EA), a combination of acupuncture and electrical stimulation, has been widely used for its effectiveness in pain relief since the 1970s [1] and later for treatment of various diseases such as depression, addiction, and gastrointestinal disorders [2], and non-medical applications including obesity treatment [3]. For stimulation, most EA systems use a pair of needles with long, thick wires connected to an external power supply to form a closed current loop. The thin (φ=2mm) needle may suffer from the inconvenient and unstable connection to the thick wire and if there are many needles, it is difficult to supply power to all needles [4]. Recently, a wirelessly-powered EA system was proposed in [4] to remove the wire connections for convenient treatment, but its wireless power harvesting generated only 8μW which is not enough for various applications [1-3]. Most EA systems use bi-phase stimulation to reduce tissue damage, electrolysis, and electrolytic degradation [5]. However, the high-precision balancing of a bi-phase current pulse is difficult to achieve because the required offset, <;10nA [6], is only on the order of 10<;sup>;-5<;/sup>; of the stimulation current level, ~1mA. Furthermore, none of the previous EA systems have any feedback mechanism to enable adaptive stimulation by showing the real-time status of the EA stimulation to the patient.
用于紧凑型电针系统的带多模态传感器的亚10na直流平衡自适应刺激IC
电针(Electro-acupuncture, EA)是一种结合针灸和电刺激的疗法,自20世纪70年代以来因其缓解疼痛的有效性而被广泛应用[1],后来又被广泛应用于治疗抑郁症、成瘾症、胃肠道疾病等多种疾病[2],以及治疗肥胖等非医学应用[3]。对于刺激,大多数EA系统使用一对长而粗的电线连接到外部电源,形成一个闭合的电流回路。细针(φ=2mm)与粗线连接不方便且不稳定,且针多时,难以向所有针供电[4]。最近,[4]中提出了一种无线供电的EA系统,为了方便处理而取消了电线连接,但其无线能量收集仅产生8μW,不足以满足各种应用[1-3]。大多数EA系统使用双相刺激来减少组织损伤、电解和电解降解[5]。然而,双相电流脉冲的高精度平衡很难实现,因为所需的偏移量为;-5;的刺激电流水平,~1mA。此外,以前的EA系统都没有任何反馈机制,通过向患者显示EA刺激的实时状态来实现自适应刺激。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信