Prostate cancer biomarker detection by using Si nanowire based electrolyte/NiOx/SiO2/n-Si sensors

Anisha Roy, J. Qiu, S. Maikap
{"title":"Prostate cancer biomarker detection by using Si nanowire based electrolyte/NiOx/SiO2/n-Si sensors","authors":"Anisha Roy, J. Qiu, S. Maikap","doi":"10.1109/VLSI-TSA.2018.8403861","DOIUrl":null,"url":null,"abstract":"Sarcosine as a prostate cancer biomarker has been detected by using Si naowire based electrolyte/NiO<inf>x</inf>/SiO<inf>2</inf>/n-Si sensor for the first time. A long nanowire (14 ^m) by chemically etched is observed by scanning electron microscope (SEM) images. A 2 nm-thick NiO<inf>x</inf> membrane on SiO<inf>2</inf>/n-Si structure shows low concentration of 1 pM H<inf>2</inf>O<inf>2</inf> sensing as well as sarcosine of 10 pM has been detected because Ni<sup>2</sup>+ oxidation state changes to Ni<sup>3</sup>+ state.","PeriodicalId":209993,"journal":{"name":"2018 International Symposium on VLSI Technology, Systems and Application (VLSI-TSA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Symposium on VLSI Technology, Systems and Application (VLSI-TSA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSI-TSA.2018.8403861","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Sarcosine as a prostate cancer biomarker has been detected by using Si naowire based electrolyte/NiOx/SiO2/n-Si sensor for the first time. A long nanowire (14 ^m) by chemically etched is observed by scanning electron microscope (SEM) images. A 2 nm-thick NiOx membrane on SiO2/n-Si structure shows low concentration of 1 pM H2O2 sensing as well as sarcosine of 10 pM has been detected because Ni2+ oxidation state changes to Ni3+ state.
基于硅纳米线电解质/NiOx/SiO2/n-Si传感器的前列腺癌生物标志物检测
本文首次采用硅纳米线电解质/NiOx/SiO2/n-Si传感器检测肌氨酸作为前列腺癌的生物标志物。利用扫描电子显微镜(SEM)观察到化学蚀刻的长纳米线(14 ^m)。在SiO2/n-Si结构上制备了2 nm厚的NiOx膜,由于Ni2+的氧化态转变为Ni3+,可以检测到低浓度的1 pM H2O2,也可以检测到10 pM的肌氨酸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信