{"title":"Reducing floodwater ingress rates through an exterior masonry wall of a domestic building","authors":"D. Beddoes, C. Booth","doi":"10.1108/SS-01-2013-0003","DOIUrl":null,"url":null,"abstract":"Purpose – Experimental field test apparatus has been used to determine the inter-variability and intra-variability floodwater ingress rates of the masonry wall of a domestic building, before and after preparation with an improved surface treatment procedure. The purpose of this paper is to discuss this issue. Design/methodology/approach – Replicated and repeated simulations of floodwater conditions (600 mm head) outside a building were created, before and after the wall was treated with a combination of mortar admixture and surface impregnation. Findings – Untreated and treated floodwater ingress rates were 4.99 litres/hour (234.99 litres/hour/m2) and 1.74 litres/hour (81.90 litres/hour/m2), respectively, and display high intra-variability before treatment. These preliminary results indicate water penetration through masonry is linked to the initial rate of absorption of brick units and perceivably the workmanship of the bricklayer. Originality/value – Reductions in floodwater penetration from outside a b...","PeriodicalId":118605,"journal":{"name":"Structural Survey","volume":"25 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Survey","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/SS-01-2013-0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
Abstract
Purpose – Experimental field test apparatus has been used to determine the inter-variability and intra-variability floodwater ingress rates of the masonry wall of a domestic building, before and after preparation with an improved surface treatment procedure. The purpose of this paper is to discuss this issue. Design/methodology/approach – Replicated and repeated simulations of floodwater conditions (600 mm head) outside a building were created, before and after the wall was treated with a combination of mortar admixture and surface impregnation. Findings – Untreated and treated floodwater ingress rates were 4.99 litres/hour (234.99 litres/hour/m2) and 1.74 litres/hour (81.90 litres/hour/m2), respectively, and display high intra-variability before treatment. These preliminary results indicate water penetration through masonry is linked to the initial rate of absorption of brick units and perceivably the workmanship of the bricklayer. Originality/value – Reductions in floodwater penetration from outside a b...