{"title":"Effect of Power Quality on Production Reliability and Stability of Water Treatment Plant at Vodovod-Osijek","authors":"Davor Junušić","doi":"10.15341/mese(2333-2581)/09.08.2022/005","DOIUrl":null,"url":null,"abstract":"Power quality issues are pervasive in most industries. The system operator and the network user are responsible for the power quality at the point of common coupling (PCC). Since a water treatment plant must operate continuously, a reliable and continuous power supply of satisfactory quality is necessary in accordance with HRN EN 50160:2012. Additionally, the electromagnetic feedback of load consumption on the power grid must be within the permitted values prescribed by the Distribution System Grid Code (Official Gazzete nos. 74/18, 52/20). The low-voltage power grid of the “Nebo Pustara” water treatment plant contains sensitive electric and electronic loads. As such, the loads require a power supply of satisfactory quality. Moreover, these loads have non-linear voltage/current characteristics and as such negatively affect power quality. In order to prevent the effects of poor power quality on the water treatment plan operation and to reduce the impermissible effect of non-linear loads on the power grid, the “Nebo Pustara” power sub-station was outfitted with a PQube3 power quality analyzer. This paper presents the results of the power quality analysis. Additionally, the paper details the actions taken in the user and distribution power grid to increase effect production reliability and stability of the water treatment plant and water supply, with the aim of reducing the negative effect on plant operation and equipment and also reducing the impermissible feedback of non-linear loads. Key words: power quality, water for human consumption, production reliability and stability of water treatment plant and water supply, Nebo Pustara, PQube3","PeriodicalId":424774,"journal":{"name":"Modern Environmental Science and Engineering","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Modern Environmental Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15341/mese(2333-2581)/09.08.2022/005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Power quality issues are pervasive in most industries. The system operator and the network user are responsible for the power quality at the point of common coupling (PCC). Since a water treatment plant must operate continuously, a reliable and continuous power supply of satisfactory quality is necessary in accordance with HRN EN 50160:2012. Additionally, the electromagnetic feedback of load consumption on the power grid must be within the permitted values prescribed by the Distribution System Grid Code (Official Gazzete nos. 74/18, 52/20). The low-voltage power grid of the “Nebo Pustara” water treatment plant contains sensitive electric and electronic loads. As such, the loads require a power supply of satisfactory quality. Moreover, these loads have non-linear voltage/current characteristics and as such negatively affect power quality. In order to prevent the effects of poor power quality on the water treatment plan operation and to reduce the impermissible effect of non-linear loads on the power grid, the “Nebo Pustara” power sub-station was outfitted with a PQube3 power quality analyzer. This paper presents the results of the power quality analysis. Additionally, the paper details the actions taken in the user and distribution power grid to increase effect production reliability and stability of the water treatment plant and water supply, with the aim of reducing the negative effect on plant operation and equipment and also reducing the impermissible feedback of non-linear loads. Key words: power quality, water for human consumption, production reliability and stability of water treatment plant and water supply, Nebo Pustara, PQube3
电能质量对Vodovod-Osijek水厂生产可靠性和稳定性的影响
电能质量问题在大多数行业都很普遍。系统操作员和网络用户对共耦合点(PCC)的电能质量负责。由于水处理厂必须连续运行,因此根据HRN EN 50160:2012,需要可靠和连续的质量令人满意的电源。此外,电网上负载消耗的电磁反馈必须在《配电系统电网规范》(74/18、52/20号官方公报)规定的允准值之内。“Nebo Pustara”水处理厂的低压电网包含敏感的电力和电子负载。因此,负载需要一个质量令人满意的电源。此外,这些负载具有非线性电压/电流特性,因此会对电能质量产生负面影响。为防止电能质量差对水处理计划运行的影响,减少非线性负荷对电网的不允许影响,“Nebo Pustara”电站安装了PQube3型电能质量分析仪。本文给出了电能质量分析的结果。此外,本文还详细介绍了用户和配电网为提高水处理厂和供水的效果生产可靠性和稳定性所采取的措施,以减少对工厂运行和设备的负面影响,并减少非线性负荷的不允许反馈。关键词:电能质量,人类生活用水,水处理厂和供水的生产可靠性和稳定性,Nebo Pustara, PQube3
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.30
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信