A case of titanium-coated pacemaker allergy in a 14-year-old patient

N. Esakova, S. Termosesov, M. Shkolnikova, A. Pampura
{"title":"A case of titanium-coated pacemaker allergy in a 14-year-old patient","authors":"N. Esakova, S. Termosesov, M. Shkolnikova, A. Pampura","doi":"10.36691/rja1567","DOIUrl":null,"url":null,"abstract":"The low informative value of the allergy testing to titanium makes it difficult to diagnose allergy to this component. The present paper describes a case report of an allergy to a titanium-coated pacemaker implanted into a 14-year-old patient. This is the first time eosinophil cationic protein and tryptase to be detected at the inflammation site while making diagnosis of allergy to titanium-coated pacemaker. The reimplantation of a gold-coated pacemaker prevents recurrence of inflammatory changes in the area of pacemaker insertion and infectious complications.","PeriodicalId":270411,"journal":{"name":"Russian Journal of Allergy","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Russian Journal of Allergy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.36691/rja1567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The low informative value of the allergy testing to titanium makes it difficult to diagnose allergy to this component. The present paper describes a case report of an allergy to a titanium-coated pacemaker implanted into a 14-year-old patient. This is the first time eosinophil cationic protein and tryptase to be detected at the inflammation site while making diagnosis of allergy to titanium-coated pacemaker. The reimplantation of a gold-coated pacemaker prevents recurrence of inflammatory changes in the area of pacemaker insertion and infectious complications.
14岁患者钛包覆起搏器过敏1例
对钛的过敏试验信息价值低,使得对该成分的过敏诊断困难。本文描述了一个病例报告过敏钛涂层起搏器植入一个14岁的病人。这是首次在诊断钛包覆起搏器过敏时在炎症部位检测到嗜酸性粒细胞阳离子蛋白和胰蛋白酶。重新植入镀金起搏器可以防止起搏器插入部位的炎症变化和感染并发症的复发。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信