{"title":"N2H4 gas detection using Langmuir-Blodgett films of a dithiolene complex on chemiresistor sensors","authors":"De-quan Yang, Run-fu Wang, Shu-ping Xie, Yun Guo, Yan Sun, C. Fan, D. Da, Haijang Wang, Hu-lin Li","doi":"10.1117/12.300642","DOIUrl":null,"url":null,"abstract":"A device based on a mono or multilayers films of a nickel dithiolene-stearyl alcohol complex built with the Langmuir- Blodgett (LB) technique has been investigated as a N2H4 gas detector. The films deposited on an aluminum electrode and the changes in the electrical properties of the film when exposed to the N2H4 gas were tested. It was found that there still a well response when the device exposed 0.5 ppm N2H4 gas at the room temperature, and the changes of electrical conductive of the film is roughly linear with N2H4 gas concentration in the lower concentration. The experimental results indicated the response time and recovery time of the sensor are less than 30 seconds.","PeriodicalId":362287,"journal":{"name":"Thin Film Physics and Applications","volume":"235 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1998-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thin Film Physics and Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.300642","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A device based on a mono or multilayers films of a nickel dithiolene-stearyl alcohol complex built with the Langmuir- Blodgett (LB) technique has been investigated as a N2H4 gas detector. The films deposited on an aluminum electrode and the changes in the electrical properties of the film when exposed to the N2H4 gas were tested. It was found that there still a well response when the device exposed 0.5 ppm N2H4 gas at the room temperature, and the changes of electrical conductive of the film is roughly linear with N2H4 gas concentration in the lower concentration. The experimental results indicated the response time and recovery time of the sensor are less than 30 seconds.
用Langmuir-Blodgett薄膜在化学电阻传感器上检测N2H4气体
采用Langmuir- Blodgett (LB)技术,研究了一种基于镍二硫烯-硬脂醇络合物单层或多层膜的装置作为N2H4气体探测器。测试了沉积在铝电极上的薄膜在N2H4气体作用下的电性能变化。实验发现,当器件在室温下暴露于0.5 ppm N2H4气体时,仍有良好的响应,且在较低浓度下,薄膜导电性随N2H4气体浓度的变化大致呈线性关系。实验结果表明,该传感器的响应时间和恢复时间均小于30秒。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信