Measurement of steady-state and transient harmonics caused by TVS

Leonhard Petzel, D. Pommerenke, S. Holland, Seyed Mostafa Mousavi, Amin Pak
{"title":"Measurement of steady-state and transient harmonics caused by TVS","authors":"Leonhard Petzel, D. Pommerenke, S. Holland, Seyed Mostafa Mousavi, Amin Pak","doi":"10.1109/EMCEurope51680.2022.9901243","DOIUrl":null,"url":null,"abstract":"This paper discusses RF harmonic distortion created by ESD protection diodes. Different measurement topologies are analyzed with a focus on measurement error. Two improvements are presented. Besides the steady-state harmonics, measurement data of transient harmonics are presented. They show that after the initial turn-on of an RF signal, the harmonics might be significantly stronger than after they settled to their steady-state value. Finally, the impact of the recovery time is analyzed.","PeriodicalId":268262,"journal":{"name":"2022 International Symposium on Electromagnetic Compatibility – EMC Europe","volume":"156 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Symposium on Electromagnetic Compatibility – EMC Europe","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMCEurope51680.2022.9901243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper discusses RF harmonic distortion created by ESD protection diodes. Different measurement topologies are analyzed with a focus on measurement error. Two improvements are presented. Besides the steady-state harmonics, measurement data of transient harmonics are presented. They show that after the initial turn-on of an RF signal, the harmonics might be significantly stronger than after they settled to their steady-state value. Finally, the impact of the recovery time is analyzed.
由TVS引起的稳态和瞬态谐波的测量
本文讨论了ESD保护二极管产生的射频谐波畸变。分析了不同的测量拓扑,重点分析了测量误差。提出了两项改进。除了稳态谐波外,还给出了暂态谐波的测量数据。他们表明,在射频信号初始开启后,谐波可能比稳定到稳态值后明显更强。最后,分析了恢复时间的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信