Superposition of Time-dependent Data for Accelerated Aging of Nuclear Power Plant Cables and Its Validity

Y. Ohki, N. Hirai, S. Okada
{"title":"Superposition of Time-dependent Data for Accelerated Aging of Nuclear Power Plant Cables and Its Validity","authors":"Y. Ohki, N. Hirai, S. Okada","doi":"10.23919/CMD54214.2022.9991591","DOIUrl":null,"url":null,"abstract":"A cable operated in a nuclear power plant (NPP) was removed to examine its degradation degree. Artificial aging was given to a similar new cable insulated with the same material so that we could simulate the degradation that the removed cable had suffered in three different manners by changing the dose rate and period of gamma-ray irradiation. For these cable samples removed or artificially aged, instrumental analyses were conducted. As a result, the validity of a method called “superposition of time-dependent data” used to give the artificial aging to simulate the aging of cables in a NPP has been confirmed.","PeriodicalId":196825,"journal":{"name":"2022 9th International Conference on Condition Monitoring and Diagnosis (CMD)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 9th International Conference on Condition Monitoring and Diagnosis (CMD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/CMD54214.2022.9991591","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

A cable operated in a nuclear power plant (NPP) was removed to examine its degradation degree. Artificial aging was given to a similar new cable insulated with the same material so that we could simulate the degradation that the removed cable had suffered in three different manners by changing the dose rate and period of gamma-ray irradiation. For these cable samples removed or artificially aged, instrumental analyses were conducted. As a result, the validity of a method called “superposition of time-dependent data” used to give the artificial aging to simulate the aging of cables in a NPP has been confirmed.
核电厂电缆加速老化时相关数据的叠加及其有效性
对某核电站运行的电缆进行了拆除,并对其降解程度进行了检测。通过改变γ射线辐照的剂量率和辐照时间,我们模拟了用相同材料绝缘的类似的新电缆在三种不同方式下所遭受的退化。对于这些被移除或人工老化的电缆样本,进行了仪器分析。研究结果证实了“时间相关数据叠加法”用于模拟核电站电缆老化的人工老化方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信