A comparison of the isotropic broadband susceptibility test method and an RS103 test on an ARC-182 radio

D. Kempf
{"title":"A comparison of the isotropic broadband susceptibility test method and an RS103 test on an ARC-182 radio","authors":"D. Kempf","doi":"10.1109/ISEMC.1994.385685","DOIUrl":null,"url":null,"abstract":"The isotropic broadband susceptibility (IBS) test method is a new radiated susceptibility method. This method uses band limited white Gaussian noise which is upconverted by performing double sideband, suppressed carrier modulation with an RF or microwave signal. This method is performed in a high Q chamber so that the test sample is uniformly radiated on all sides by the field as in a mode-stirred chamber. Testing was performed on an ARC-182 radio with the IBS method in order to determine if the IBS method could find susceptibilities on equipment with extremely narrow failure bandwidths. The results of the testing were compared with the results of an RS103 test performed in accordance with MIL-STD-462D on the same ARC-182 radio. Testing was performed as an investigation to evaluate the method as a possible alternate method to RS103.<<ETX>>","PeriodicalId":154914,"journal":{"name":"Proceedings of IEEE Symposium on Electromagnetic Compatibility","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1994-08-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1994.385685","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

Abstract

The isotropic broadband susceptibility (IBS) test method is a new radiated susceptibility method. This method uses band limited white Gaussian noise which is upconverted by performing double sideband, suppressed carrier modulation with an RF or microwave signal. This method is performed in a high Q chamber so that the test sample is uniformly radiated on all sides by the field as in a mode-stirred chamber. Testing was performed on an ARC-182 radio with the IBS method in order to determine if the IBS method could find susceptibilities on equipment with extremely narrow failure bandwidths. The results of the testing were compared with the results of an RS103 test performed in accordance with MIL-STD-462D on the same ARC-182 radio. Testing was performed as an investigation to evaluate the method as a possible alternate method to RS103.<>
各向同性宽带磁化率测试方法与RS103测试在ARC-182无线电上的比较
各向同性宽带磁化率(IBS)测试方法是一种新的辐射磁化率测试方法。该方法利用带限高斯白噪声,通过对射频或微波信号进行双边带抑制载波调制进行上转换。这种方法是在高Q室中进行的,这样测试样品就像在模式搅拌室中一样,被场均匀地向四面辐射。为了确定IBS方法是否能够在故障带宽极窄的设备上发现敏感性,在ARC-182无线电上使用IBS方法进行了测试。将测试结果与在同一ARC-182无线电上按照MIL-STD-462D进行的RS103测试结果进行比较。试验作为一项调查,以评估该方法作为RS103的可能替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信