{"title":"Generation of critical acoustic pulses in high-voltage insulators due to induced fields of partial discharges","authors":"V. Golenishchev-kutuzov, A. Golenishchev-Kutuzov, A. V. Semenikov, G. D. Mardanov, R. Kalimullin, D. Ivanov","doi":"10.30724/1998-9903-2023-25-1-154-165","DOIUrl":null,"url":null,"abstract":"THE PURPOSE of the article is to discuss an updated survey of the technical condition of porcelain high-voltage insulators of the type IOS 110/400, which had defects with partial discharge intensities above 4 nC, at Tatenergo substations. The experiments were carried out with simultaneous use of electromagnetic and acoustic research methods.During the analysis of the RESULTS obtained, the influence of the fields of previous powerful partial discharges on the technical condition of high-voltage insulators was established. The physical features of detecting powerful partial discharges by electromagnetic and acoustic methods have been studied. The conducted studies allow us to draw the following.CONCLUSIONS: the previous partial discharges can create additional long-lived electric fields on the dielectric surfaces of defects that exceed the field of the applied operating voltage in intensity; the necessity of using both physical methods simultaneously in the examination of high-voltage insulators in operation is shown.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power engineering: research, equipment, technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30724/1998-9903-2023-25-1-154-165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

THE PURPOSE of the article is to discuss an updated survey of the technical condition of porcelain high-voltage insulators of the type IOS 110/400, which had defects with partial discharge intensities above 4 nC, at Tatenergo substations. The experiments were carried out with simultaneous use of electromagnetic and acoustic research methods.During the analysis of the RESULTS obtained, the influence of the fields of previous powerful partial discharges on the technical condition of high-voltage insulators was established. The physical features of detecting powerful partial discharges by electromagnetic and acoustic methods have been studied. The conducted studies allow us to draw the following.CONCLUSIONS: the previous partial discharges can create additional long-lived electric fields on the dielectric surfaces of defects that exceed the field of the applied operating voltage in intensity; the necessity of using both physical methods simultaneously in the examination of high-voltage insulators in operation is shown.
高压绝缘子中局部放电感应场产生的临界声脉冲
本文的目的是讨论在Tatenergo变电站的ios110 /400型高压瓷绝缘子的技术状况的最新调查,该瓷绝缘子存在局部放电强度大于4nc的缺陷。实验同时采用了电磁和声学研究方法。通过对所得结果的分析,确定了以往强局部放电的场对高压绝缘子技术条件的影响。研究了电磁法和声波法探测强局部放电的物理特性。所进行的研究使我们可以得出以下结论。结论:先前的局部放电可以在缺陷的介电表面产生额外的长寿命电场,其强度超过所施加的工作电压;说明了高压绝缘子在运行过程中,两种物理方法同时使用的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信