Performance comparison of different motion correction algorithms used in cardiac SPECT imaging

M. Tabrizi, K. Dong, A. Movahed
{"title":"Performance comparison of different motion correction algorithms used in cardiac SPECT imaging","authors":"M. Tabrizi, K. Dong, A. Movahed","doi":"10.1109/ITCC.2001.918844","DOIUrl":null,"url":null,"abstract":"We evaluate the performance and accuracy of different motion correction algorithms used in nuclear cardiac imaging. Three algorithms used in automated tracking techniques are the diverging square (DS); diverging circles (DC); and self-adaptive masking methods (SM). The observation of the tracking process over the images acquired (specifically for this study with introduced patient motion) in nuclear cardiac laboratory showed that the DC and SM algorithms perform better when compared with the DS algorithm. It was shown that the SM method gains a good tolerance of low signal to noise ratio (SNR) images and is also robust in the presence of abrupt motion.","PeriodicalId":318295,"journal":{"name":"Proceedings International Conference on Information Technology: Coding and Computing","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-04-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings International Conference on Information Technology: Coding and Computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITCC.2001.918844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We evaluate the performance and accuracy of different motion correction algorithms used in nuclear cardiac imaging. Three algorithms used in automated tracking techniques are the diverging square (DS); diverging circles (DC); and self-adaptive masking methods (SM). The observation of the tracking process over the images acquired (specifically for this study with introduced patient motion) in nuclear cardiac laboratory showed that the DC and SM algorithms perform better when compared with the DS algorithm. It was shown that the SM method gains a good tolerance of low signal to noise ratio (SNR) images and is also robust in the presence of abrupt motion.
不同运动校正算法在心脏SPECT成像中的性能比较
我们评估不同的运动校正算法的性能和准确性用于核心脏成像。自动跟踪技术中使用的三种算法是发散平方法(DS);发散圆(DC);和自适应掩蔽方法(SM)。通过对核心脏实验室获得的图像(特别是本研究中引入患者运动的图像)的跟踪过程观察,与DS算法相比,DC和SM算法的跟踪效果更好。结果表明,该方法对低信噪比的图像具有良好的容忍度,对突发运动也具有较强的鲁棒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信