PSCAD validation of delta-wye transformer as a harmonic filter for THD mitigation of line currents in three-phase bridge rectifier

A. N. Arvindan, V. Muthukumarasamy
{"title":"PSCAD validation of delta-wye transformer as a harmonic filter for THD mitigation of line currents in three-phase bridge rectifier","authors":"A. N. Arvindan, V. Muthukumarasamy","doi":"10.1109/ICSET.2012.6357382","DOIUrl":null,"url":null,"abstract":"The 3-phase diode bridge rectifier has the least line current distortion among 6-pulse rectifiers; however, its total harmonic distortion (THD) of 31.08% violates power quality standards. This paper reports distortion reduction by lowering magnitudes of harmonics in the line currents using a delta-wye transformer between the 3-phase utility and the diode bridge rectifier. The leakage inductances of the transformer windings provide a filtering effect on the line current harmonics thus providing THD mitigation of utility line currents. The efficacy of the technique is proved by Power Systems Computer Aided Design (PSCAD) simulations considering the bridge rectifier with and without the delta-wye transformer of vector group Dyl. Experimental results without and with the Dyl transformer feeding the diode bridge rectifier are presented.","PeriodicalId":256740,"journal":{"name":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","volume":"369 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Third International Conference on Sustainable Energy Technologies (ICSET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSET.2012.6357382","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The 3-phase diode bridge rectifier has the least line current distortion among 6-pulse rectifiers; however, its total harmonic distortion (THD) of 31.08% violates power quality standards. This paper reports distortion reduction by lowering magnitudes of harmonics in the line currents using a delta-wye transformer between the 3-phase utility and the diode bridge rectifier. The leakage inductances of the transformer windings provide a filtering effect on the line current harmonics thus providing THD mitigation of utility line currents. The efficacy of the technique is proved by Power Systems Computer Aided Design (PSCAD) simulations considering the bridge rectifier with and without the delta-wye transformer of vector group Dyl. Experimental results without and with the Dyl transformer feeding the diode bridge rectifier are presented.
三相桥式整流器中三角型变压器作为谐波滤波器抑制线路电流THD的PSCAD验证
在6脉冲整流器中,三相二极管桥式整流器具有最小的线路电流畸变;但其总谐波失真(THD)达31.08%,不符合电能质量标准。本文报道了通过在三相电源和二极管桥式整流器之间使用三角眼变压器降低线路电流谐波的幅度来降低失真的方法。变压器绕组的漏电电感提供了对线路电流谐波的滤波效果,从而提供了公用线路电流的THD缓解。通过电力系统计算机辅助设计(PSCAD)仿真,验证了该方法的有效性。给出了不使用和使用Dyl变压器供电二极管桥式整流器的实验结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信