Harmonic Ratio and Detrended Fluctuation Analysis Aided Reliable Estimation of contamination Level On Outdoor Suspension Insulators

Padam Dhar Dwivedi, Ariiit Baral, S. Dutta
{"title":"Harmonic Ratio and Detrended Fluctuation Analysis Aided Reliable Estimation of contamination Level On Outdoor Suspension Insulators","authors":"Padam Dhar Dwivedi, Ariiit Baral, S. Dutta","doi":"10.1109/CONIT55038.2022.9847920","DOIUrl":null,"url":null,"abstract":"The Suspension insulator is an indispensable component in a power system network. With the increasing electricity demand, it's the utility's responsibility to provide reliable power to the consumer. Thus, condition monitoring of overhead insulators is necessary because contaminants present in the environment cause insulation flashover and affect the power system operation. In the current work, an 11kV porcelain disc insulator is used, artificially contaminated. After that, Detrended Fluctuation Analysis (DFA) and Harmonic Ratio method are applied to estimate the contamination level using surface leakage current data.","PeriodicalId":270445,"journal":{"name":"2022 2nd International Conference on Intelligent Technologies (CONIT)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 2nd International Conference on Intelligent Technologies (CONIT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CONIT55038.2022.9847920","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Suspension insulator is an indispensable component in a power system network. With the increasing electricity demand, it's the utility's responsibility to provide reliable power to the consumer. Thus, condition monitoring of overhead insulators is necessary because contaminants present in the environment cause insulation flashover and affect the power system operation. In the current work, an 11kV porcelain disc insulator is used, artificially contaminated. After that, Detrended Fluctuation Analysis (DFA) and Harmonic Ratio method are applied to estimate the contamination level using surface leakage current data.
谐波比和趋势波动分析辅助室外悬架绝缘子污染程度的可靠估计
悬吊绝缘子是电网中不可缺少的重要组成部分。随着电力需求的增加,为消费者提供可靠的电力是公用事业公司的责任。因此,对架空绝缘子进行状态监测是必要的,因为环境中存在的污染物会引起绝缘闪络并影响电力系统的运行。在目前的工作中,使用11kV瓷盘绝缘子,人为污染。然后,利用表面泄漏电流数据,采用去趋势波动分析(DFA)和谐波比法估计污染程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信