S. Rawtani, S. Agarwal, H. Minhas, Sashi Prakash, A. Banerjee
{"title":"Retrieval Of A Fractured And Retained Percutaneous Coronary Angioplasty Catheter On Beating Perfused Heart","authors":"S. Rawtani, S. Agarwal, H. Minhas, Sashi Prakash, A. Banerjee","doi":"10.5580/212","DOIUrl":null,"url":null,"abstract":"A fractured and retained percutaneous transluminal coronary angioplasty catheter was successfully removed on a perfused beating heart with concomitant bypass grafting. We believe this is the first report in English literature of such an operation on a beating heart.Broken and retained percutaneous transluminal coronary angioplasty balloon catheter is a rare but serious complication of interventional cardiology. The presence of a calcified proximal lesion hinders withdrawal of the broken catheter. It requires retrieval and emergency coronary bypass grafting to prevent further complications.","PeriodicalId":330833,"journal":{"name":"The Internet Journal of Thoracic and Cardiovascular Surgery","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Internet Journal of Thoracic and Cardiovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5580/212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A fractured and retained percutaneous transluminal coronary angioplasty catheter was successfully removed on a perfused beating heart with concomitant bypass grafting. We believe this is the first report in English literature of such an operation on a beating heart.Broken and retained percutaneous transluminal coronary angioplasty balloon catheter is a rare but serious complication of interventional cardiology. The presence of a calcified proximal lesion hinders withdrawal of the broken catheter. It requires retrieval and emergency coronary bypass grafting to prevent further complications.