Effect of Titanium Tetrafluoride on Degree of Conversion and Bond Strength of an Orthodontic Primer

M. F. Badawi, T. Soliman
{"title":"Effect of Titanium Tetrafluoride on Degree of Conversion and Bond Strength of an Orthodontic Primer","authors":"M. F. Badawi, T. Soliman","doi":"10.21608/mjd.2023.301971","DOIUrl":null,"url":null,"abstract":": Objective: To evaluate the degree of conversion (DC), and orthodontic bracket shear bond strength (SBS) after the incorporation of 3 wt.% TiF4 into an orthodontic primer. Materials and Methods: According to the concentration of TiF4 within the orthodontic primer, there were two groups: the control (TF0C) and experimental groups (TF3C) (0&3 wt.% TiF4 respectively). The DC was evaluated for each group using FTIR. Ten orthodontic brackets were bonded using each concentration to the clean and etched enamel buccal surface. The SBS test was performed in an Instron universal testing machine, using a chisel positioned at the junction interface with a speed of 1.0 mm/min. Results: The DC was not significantly affected. TF3C (5.13±0.55) had the lowest SBS values in comparison to the control group (8.03±1.56). Conclusions: Incorporation of 3 wt.% of TiF4 within the primer of 3-step etch and rinse orthodontic adhesive was not recommended. Although it did not affect the degree of conversion, the bonding potency was greatly compromised.","PeriodicalId":308616,"journal":{"name":"Mansoura Journal of Dentistry","volume":"7 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mansoura Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/mjd.2023.301971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

: Objective: To evaluate the degree of conversion (DC), and orthodontic bracket shear bond strength (SBS) after the incorporation of 3 wt.% TiF4 into an orthodontic primer. Materials and Methods: According to the concentration of TiF4 within the orthodontic primer, there were two groups: the control (TF0C) and experimental groups (TF3C) (0&3 wt.% TiF4 respectively). The DC was evaluated for each group using FTIR. Ten orthodontic brackets were bonded using each concentration to the clean and etched enamel buccal surface. The SBS test was performed in an Instron universal testing machine, using a chisel positioned at the junction interface with a speed of 1.0 mm/min. Results: The DC was not significantly affected. TF3C (5.13±0.55) had the lowest SBS values in comparison to the control group (8.03±1.56). Conclusions: Incorporation of 3 wt.% of TiF4 within the primer of 3-step etch and rinse orthodontic adhesive was not recommended. Although it did not affect the degree of conversion, the bonding potency was greatly compromised.
四氟化钛对正畸处理剂转化度和粘结强度的影响
目的:评价3 wt.% TiF4加入正畸引物后正畸托槽剪切粘接强度(SBS)和转化度(DC)。材料与方法:根据正畸引物中TiF4的浓度分为两组:对照组(TF0C)和实验组(TF3C)(分别为TiF4的0%和3%)。采用FTIR评价各组DC。使用每种浓度将10个正畸托槽粘接在清洁和蚀刻的牙釉质颊表面。SBS测试在Instron万能试验机上进行,使用定位在连接处的凿子,速度为1.0 mm/min。结果:对DC无明显影响。TF3C组的SBS值(5.13±0.55)低于对照组(8.03±1.56)。结论:三步蚀刻冲洗正畸粘接剂底物中不建议掺入3 wt.%的TiF4。虽然它不影响转化的程度,但极大地损害了键合能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信