{"title":"Miniaturization of low-power constant-current converter by applying a height-reduced transformer","authors":"S. Ohzora, T. Koyashiki","doi":"10.1109/PESC.1988.18253","DOIUrl":null,"url":null,"abstract":"A method is described for designing a height-reduced transformer suitable for mounting on a hybrid IC substrate. This is achieved by using a leakage inductance equation that reflects the effects of the core shape parameters as well as the transformer itself. The resulting height-reduced transformer allows the converter size to be reduced to 7/10 that of a converter using a conventional transformer.<<ETX>>","PeriodicalId":283605,"journal":{"name":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","volume":"87 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1988-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"PESC '88 Record., 19th Annual IEEE Power Electronics Specialists Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PESC.1988.18253","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
A method is described for designing a height-reduced transformer suitable for mounting on a hybrid IC substrate. This is achieved by using a leakage inductance equation that reflects the effects of the core shape parameters as well as the transformer itself. The resulting height-reduced transformer allows the converter size to be reduced to 7/10 that of a converter using a conventional transformer.<>