The establishment of detecting carbohydrate antigen 125 (CA125) with immunofluorescence chromatography

Haitao Gong, Jiakun Cao, Sheng Tang
{"title":"The establishment of detecting carbohydrate antigen 125 (CA125) with immunofluorescence chromatography","authors":"Haitao Gong, Jiakun Cao, Sheng Tang","doi":"10.1109/ICARM.2017.8273157","DOIUrl":null,"url":null,"abstract":"This study was designed to develop a immunofluorescence chromatography kit for detection of CA125 in human serum, and to evaluate the method performance. The fluorescent polystyrene particle conjugated with the monoclonal antibody MIC05 was used as a fluorescent label. The monoclonal antibody MIC06 and mouse anti-rabbit IgG were immobilized on the nitrocellulose membrane as the test line and control line. The linear response rang of the method to detect the serum CA125 was 0.56–1000U/ml. And the intra-and inter-assay coefficient were 5.39% and 10.3%. Total 1200 samples were tested by the immunofluorescence chromatography kit, and the overall coincidence rate was 94.63%. The positive coincidence rate was 92.48%, the negative coincidence rate was 95.64%, and the Kappa value surpassed 0.8, which indicated that there was no significant difference between the results of the immunofluorescence chromatography kit and Elisa kit. In conclusion, the immunofluorescence chromatography kit for assaying CA125 provided high sensitivity, rapid, simple operation, low cost, single-servings and can be extensively used for clinical operarions.","PeriodicalId":416846,"journal":{"name":"International Conference on Advanced Robotics and Mechatronics","volume":"57 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Advanced Robotics and Mechatronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICARM.2017.8273157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study was designed to develop a immunofluorescence chromatography kit for detection of CA125 in human serum, and to evaluate the method performance. The fluorescent polystyrene particle conjugated with the monoclonal antibody MIC05 was used as a fluorescent label. The monoclonal antibody MIC06 and mouse anti-rabbit IgG were immobilized on the nitrocellulose membrane as the test line and control line. The linear response rang of the method to detect the serum CA125 was 0.56–1000U/ml. And the intra-and inter-assay coefficient were 5.39% and 10.3%. Total 1200 samples were tested by the immunofluorescence chromatography kit, and the overall coincidence rate was 94.63%. The positive coincidence rate was 92.48%, the negative coincidence rate was 95.64%, and the Kappa value surpassed 0.8, which indicated that there was no significant difference between the results of the immunofluorescence chromatography kit and Elisa kit. In conclusion, the immunofluorescence chromatography kit for assaying CA125 provided high sensitivity, rapid, simple operation, low cost, single-servings and can be extensively used for clinical operarions.
免疫荧光色谱法检测碳水化合物抗原125 (CA125)的建立
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信