Absorber for measuring the transmission of a polycapillary focusing optical lens

Haoran Wang, P. Zhou, Shuang Zhang, Zhiguo Liu
{"title":"Absorber for measuring the transmission of a polycapillary focusing optical lens","authors":"Haoran Wang, P. Zhou, Shuang Zhang, Zhiguo Liu","doi":"10.1117/12.2584898","DOIUrl":null,"url":null,"abstract":"The combination of an absorption sheet, a high count rate detector and a low-power micro-focus source is used to simultaneously measure the transmission of the polycapillary focusing optical lens in a large energy range. This method places the micro-focus source, the absorber and the detector in a line, has highly operability in actual measurement. The X-rays below 8 keV were completely absorbed when adding the aluminum absorption sheet, and the transmission efficiency of the lens to X-rays below 8 keV was not measured. After the absorption sheet is added, the attenuation of the X-ray is not simply an exponential decay, but also the Compton scattering effect was involved.","PeriodicalId":370739,"journal":{"name":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Photonics and Optical Engineering and the Annual West China Photonics Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2584898","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The combination of an absorption sheet, a high count rate detector and a low-power micro-focus source is used to simultaneously measure the transmission of the polycapillary focusing optical lens in a large energy range. This method places the micro-focus source, the absorber and the detector in a line, has highly operability in actual measurement. The X-rays below 8 keV were completely absorbed when adding the aluminum absorption sheet, and the transmission efficiency of the lens to X-rays below 8 keV was not measured. After the absorption sheet is added, the attenuation of the X-ray is not simply an exponential decay, but also the Compton scattering effect was involved.
用于测量多毛细聚焦光学透镜透射率的吸收器
采用吸收片、高计数率检测器和低功率微聚焦光源组合,在大能量范围内同时测量多毛细聚焦光学透镜的透射率。该方法将微聚焦源、吸收器和探测器串联在一起,在实际测量中具有很强的可操作性。添加铝吸收片后,8 keV以下的x射线被完全吸收,未测量透镜对8 keV以下x射线的透射效率。加入吸收片后,x射线的衰减不仅仅是指数衰减,还涉及到康普顿散射效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信