Long Zhao, Jia Xie, Zhenshan Liu, Hui Liu, Fenglong Sun
{"title":"The Research on Non-linearity and Sensitivity of Current Sensor Based on Diamond Magnetometer","authors":"Long Zhao, Jia Xie, Zhenshan Liu, Hui Liu, Fenglong Sun","doi":"10.1109/CCPQT56151.2022.00066","DOIUrl":null,"url":null,"abstract":"Nitrogen-vacancy (NV) center is a kind of point defect, which consist of a nitrogen atom and a vacancy distributed in diamond. Under the irradiation of 532nm laser, the NV center can emit fluorescence with 640nm∼800nm wavelength, while the intensity of fluorescence could be influenced by microwave and magnetic field. This feature can be used to realize high-precision magnetic field measurement. The NV center current sensor has the characteristics of ultrahigh precision and long-term stability, which leads to a great application potential such as current transformers. In the test, it was found that the NV center current sensor will have a non-linear effect under high current, resulting in a limitation in current sensing application. This paper simulates the non-linear response of NV current sensor, and proposes some improvement ways based on the simulation results.","PeriodicalId":235893,"journal":{"name":"2022 International Conference on Computing, Communication, Perception and Quantum Technology (CCPQT)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Computing, Communication, Perception and Quantum Technology (CCPQT)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCPQT56151.2022.00066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
Nitrogen-vacancy (NV) center is a kind of point defect, which consist of a nitrogen atom and a vacancy distributed in diamond. Under the irradiation of 532nm laser, the NV center can emit fluorescence with 640nm∼800nm wavelength, while the intensity of fluorescence could be influenced by microwave and magnetic field. This feature can be used to realize high-precision magnetic field measurement. The NV center current sensor has the characteristics of ultrahigh precision and long-term stability, which leads to a great application potential such as current transformers. In the test, it was found that the NV center current sensor will have a non-linear effect under high current, resulting in a limitation in current sensing application. This paper simulates the non-linear response of NV current sensor, and proposes some improvement ways based on the simulation results.