Integrated Operation of Conservation Voltage Reduction and Network Reconfiguration in PV-Rich Distribution Network considering Soft Open Point Impact

Vijay Babu Pamshetti, S. Singh, Amit Kumar Thaku, S. P. Singh, Vinod Kumar Bussa
{"title":"Integrated Operation of Conservation Voltage Reduction and Network Reconfiguration in PV-Rich Distribution Network considering Soft Open Point Impact","authors":"Vijay Babu Pamshetti, S. Singh, Amit Kumar Thaku, S. P. Singh, Vinod Kumar Bussa","doi":"10.1109/IAS.2019.8912415","DOIUrl":null,"url":null,"abstract":"High penetration of photovoltaic (PV) generation in distribution system exacerbates the over voltage issue and violation of thermal limit of distribution lines. Further, this increased penetration leads to negative impact on system losses. In order to overcome above mentioned problems, this paper introduces the integrated operation of conservation voltage reduction (CVR) and distribution network reconfiguration (DNR) for advance distribution management system (ADMS) application. Besides, impact of advanced flexible power electronic devices such as PV smart inverter and soft open point (SOP) on energy consumption and losses have been studied. The proposed methodology has been implemented on modified 33 bus distribution system. The test results demonstrate the significant impact of the proposed integrated operation on voltage violation, energy losses and energy consumption.","PeriodicalId":376719,"journal":{"name":"2019 IEEE Industry Applications Society Annual Meeting","volume":"297 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Industry Applications Society Annual Meeting","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IAS.2019.8912415","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

High penetration of photovoltaic (PV) generation in distribution system exacerbates the over voltage issue and violation of thermal limit of distribution lines. Further, this increased penetration leads to negative impact on system losses. In order to overcome above mentioned problems, this paper introduces the integrated operation of conservation voltage reduction (CVR) and distribution network reconfiguration (DNR) for advance distribution management system (ADMS) application. Besides, impact of advanced flexible power electronic devices such as PV smart inverter and soft open point (SOP) on energy consumption and losses have been studied. The proposed methodology has been implemented on modified 33 bus distribution system. The test results demonstrate the significant impact of the proposed integrated operation on voltage violation, energy losses and energy consumption.
考虑软开点影响的富光伏配电网保护降压与网络重构一体化运行
光伏发电在配电网中的高渗透加剧了配电网的过电压问题和热极限问题。此外,这种增加的渗透会对系统损失产生负面影响。为了克服上述问题,本文介绍了超前配电管理系统(ADMS)应用中的节能降压(CVR)与配电网重构(DNR)一体化运行。此外,还研究了光伏智能逆变器、软开点(SOP)等先进柔性电力电子设备对能耗和损耗的影响。该方法已在改进后的33总线配电系统上实施。试验结果表明,所提出的一体化运行对电压违和、能量损失和能耗有显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信