{"title":"Evaluasi Pengaruh Tegangan Kerja Generator terhadap Kualitas Tegangan Jaringan pada PT.PLN (Persero) Area Luwuk","authors":"Herman Nawir, M. Yunus, Ibnu Amir","doi":"10.31963/sinergi.v19i2.3018","DOIUrl":null,"url":null,"abstract":"One of the service quality parameters is that the voltage supplied to consumers is always at the set value, which is 20 kV for medium voltage and 380/220 Volt for low voltage, many factors can affect the magnitude of the voltage starting when the voltage is generated by the generator, the process distribution to consumers by using a conductor and the amount of load that is on the feeder. This study aims to determine how much influence the generator output voltage has on changes in voltage in the medium voltage network and how much voltage drop occurs at the JTM until it reaches the consumer. The results show that the generator output voltage will affect the base voltage, the greater the generator output voltage, the greater the base voltage and operating voltage of the system. The voltage drop along the industrial feeder before the generator voltage is increased is 281,856 Volts or if it is used as a percentage of 1.441% but when the generator output voltage is increased the voltage drop in the industrial feeder decreases by 277.016 Volts or if it is used as a percentage of 1.392%.","PeriodicalId":315673,"journal":{"name":"Jurnal Teknik Mesin Sinergi","volume":"117 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Teknik Mesin Sinergi","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31963/sinergi.v19i2.3018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

One of the service quality parameters is that the voltage supplied to consumers is always at the set value, which is 20 kV for medium voltage and 380/220 Volt for low voltage, many factors can affect the magnitude of the voltage starting when the voltage is generated by the generator, the process distribution to consumers by using a conductor and the amount of load that is on the feeder. This study aims to determine how much influence the generator output voltage has on changes in voltage in the medium voltage network and how much voltage drop occurs at the JTM until it reaches the consumer. The results show that the generator output voltage will affect the base voltage, the greater the generator output voltage, the greater the base voltage and operating voltage of the system. The voltage drop along the industrial feeder before the generator voltage is increased is 281,856 Volts or if it is used as a percentage of 1.441% but when the generator output voltage is increased the voltage drop in the industrial feeder decreases by 277.016 Volts or if it is used as a percentage of 1.392%.
评估发电机工作电压对Luwuk区域PT.PLN (Persero)网络质量的影响
其中一个服务质量参数是提供给用户的电压始终处于设定值,即中压为20 kV,低压为380/220伏,许多因素都会影响发电机产生电压时开始电压的大小,使用导体向用户分配的过程以及馈线上的负载量。本研究旨在确定发电机输出电压对中压网络电压变化的影响程度,以及在到达消费者之前在JTM处发生多少电压降。结果表明,发电机输出电压会影响基极电压,发电机输出电压越大,系统的基极电压和工作电压越大。在发电机电压增加之前,沿工业馈线的电压降为281,856伏,或者如果它以1.441%的百分比使用,但是当发电机输出电压增加时,工业馈线的电压降降低了277.016伏,或者如果它以1.392%的百分比使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信