Natural timestamping using electrical power grid: demo abstract

S. Viswanathan, Yang Li, Rui Tan
{"title":"Natural timestamping using electrical power grid: demo abstract","authors":"S. Viswanathan, Yang Li, Rui Tan","doi":"10.1145/3055031.3055039","DOIUrl":null,"url":null,"abstract":"The continuous fluctuation of electric network frequency (ENF) presents a fingerprint indicative of time, which we call natural timestamp. This live demo demonstrates the accuracy of the natural timestamps obtained by four wired voltage sensors and four wireless electromagnetic radiation (EMR) sensors that are geographically distributed in Singapore. The voltage sensors and the EMR sensors capture the minute fluctuations of the length of each voltage cycle and the average ENF over every 50 voltage cycles, respectively. The evaluation in our prior studies [1, 3] has shown that the natural timestamps recorded by the voltage sensors and the EMR sensors give sub-millisecond and sub-second average time errors, respectively. This demo will also show their time errors.","PeriodicalId":206082,"journal":{"name":"Proceedings of the 16th ACM/IEEE International Conference on Information Processing in Sensor Networks","volume":"21 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 16th ACM/IEEE International Conference on Information Processing in Sensor Networks","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3055031.3055039","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The continuous fluctuation of electric network frequency (ENF) presents a fingerprint indicative of time, which we call natural timestamp. This live demo demonstrates the accuracy of the natural timestamps obtained by four wired voltage sensors and four wireless electromagnetic radiation (EMR) sensors that are geographically distributed in Singapore. The voltage sensors and the EMR sensors capture the minute fluctuations of the length of each voltage cycle and the average ENF over every 50 voltage cycles, respectively. The evaluation in our prior studies [1, 3] has shown that the natural timestamps recorded by the voltage sensors and the EMR sensors give sub-millisecond and sub-second average time errors, respectively. This demo will also show their time errors.
利用电网的自然时间戳:演示摘要
电网频率的连续波动呈现出时间的指纹,我们称之为自然时间戳。这个现场演示演示了地理上分布在新加坡的四个有线电压传感器和四个无线电磁辐射(EMR)传感器获得的自然时间戳的准确性。电压传感器和EMR传感器分别捕获每个电压周期长度的微小波动和每50个电压周期的平均ENF。我们之前的研究[1,3]的评估表明,电压传感器和EMR传感器记录的自然时间戳分别给出亚毫秒和亚秒的平均时间误差。这个演示还将显示它们的时间误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信