{"title":"WPŁYW KIERUNKU I PRĘDKOŚCI WIATRU NA PARAMETRY PRACY WYWIETRZAKA GRAWITACYJNEGO S-160","authors":"A. Deska, A. Rubnikowicz","doi":"10.17512/znb.2020.1.04","DOIUrl":null,"url":null,"abstract":"Designing industrial buildings that use prefabricated ceilings made of TT slabs, is a complex issue. In professional practice, typical (catalog) TT floor solutions are used in production lines, warehouse buildings and cement plants. The article presents a comparative analysis of a cross-section of the prefabricated ceiling span, pre-tensioned pre-stressed, slab-rib type TT ceiling in an industrial building with a mullion and transom structure. The prefabricated TT slabs are produced from reinforced concrete beams. The slabs width is constant at 240 cm and the span is assumed to be 12.0 meters. The subject of structural analysis is the selection of an appropriate cross-section of the prefabricated element, the amount of pre-stressing reinforcement required, the concrete class, and on this basis, check the load limits ULS and serviceability limit SLS according to applicable Eurocodes. The analysis was conducted on the basis of the adopted computational model and carried out detailed strength calculations.","PeriodicalId":354926,"journal":{"name":"Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeszyty Naukowe Politechniki Częstochowskiej. Budownictwo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17512/znb.2020.1.04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Designing industrial buildings that use prefabricated ceilings made of TT slabs, is a complex issue. In professional practice, typical (catalog) TT floor solutions are used in production lines, warehouse buildings and cement plants. The article presents a comparative analysis of a cross-section of the prefabricated ceiling span, pre-tensioned pre-stressed, slab-rib type TT ceiling in an industrial building with a mullion and transom structure. The prefabricated TT slabs are produced from reinforced concrete beams. The slabs width is constant at 240 cm and the span is assumed to be 12.0 meters. The subject of structural analysis is the selection of an appropriate cross-section of the prefabricated element, the amount of pre-stressing reinforcement required, the concrete class, and on this basis, check the load limits ULS and serviceability limit SLS according to applicable Eurocodes. The analysis was conducted on the basis of the adopted computational model and carried out detailed strength calculations.