On the suitability of a Two-Pulse Synthesis model for photoplethysmograph signal analysis in Public cardiac care program

D. Goswami, K. Chaudhuri, J. Mukherjee
{"title":"On the suitability of a Two-Pulse Synthesis model for photoplethysmograph signal analysis in Public cardiac care program","authors":"D. Goswami, K. Chaudhuri, J. Mukherjee","doi":"10.1109/ICSMB.2010.5735388","DOIUrl":null,"url":null,"abstract":"This paper presents a non-invasive, preventive approach to measure arterial parameters by analysis of photoplethysmograph (PPG) signals. A recently proposed Two Pulse Synthesis (TPS) model [Goswami 2010a] has been used to measure pulse wave velocity (PWV) and several new parameters of normal and diseased subjects having hypertension or diabetes or both. Results, presented through tables and figures, indicate the merits of TPS model. A scheme for integration of cardiac care for rural people has been outlined. Longitudinal studies using the TPS model has also been advocated as a part of cardiac care supported by a set of experimental results.","PeriodicalId":297136,"journal":{"name":"2010 International Conference on Systems in Medicine and Biology","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 International Conference on Systems in Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSMB.2010.5735388","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper presents a non-invasive, preventive approach to measure arterial parameters by analysis of photoplethysmograph (PPG) signals. A recently proposed Two Pulse Synthesis (TPS) model [Goswami 2010a] has been used to measure pulse wave velocity (PWV) and several new parameters of normal and diseased subjects having hypertension or diabetes or both. Results, presented through tables and figures, indicate the merits of TPS model. A scheme for integration of cardiac care for rural people has been outlined. Longitudinal studies using the TPS model has also been advocated as a part of cardiac care supported by a set of experimental results.
关于在公共心脏保健项目中光容积脉搏波信号分析的双脉冲合成模型的适用性
本文介绍了一种通过分析光容积脉搏波(PPG)信号来测量动脉参数的无创、预防性方法。最近提出的双脉冲合成(Two Pulse Synthesis, TPS)模型[Goswami 2010a]被用于测量高血压或糖尿病患者的脉搏波速度(Pulse wave velocity, PWV)和一些新的参数。通过表格和图表显示了TPS模型的优点。制定了农村人口心脏保健一体化方案。采用TPS模型的纵向研究也被提倡作为心脏护理的一部分,并得到了一系列实验结果的支持。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信