{"title":"Auto and cross correlation measurements of femtosecond laser beams in SRS microscope","authors":"R. Ranjan, M. Ferrara, L. Sirleto","doi":"10.1109/ICOP49690.2020.9300325","DOIUrl":null,"url":null,"abstract":"Ultrafast lasers are increasing their range of applications. In non-linear optical microscopy, the laser beam properties can influence the non-linear contrast efficiency and the image quality, so monitoring of the output waveform is often required.In order to obtain images, in Stimulated Raman Scattering (SRS) microscopy, two collinear laser beams, a high-power pump laser and a low power Stokes laser with different frequencies (ωL> ωS) are focused into a sample. In this paper the two laser sources, in our case a femtosecond Ti:Sapphire (Ti:Sa) oscillator and a femtosecond synchronized optical parametric oscillator (OPO) are characterized by non-linear interferometric measurements. Taking advantage of two-photon absorption (TPA), autocorrelation measurements of each laser beam and cross correlation measurements of Ti:Sa and OPO are carried out. Results are reported and discussed.","PeriodicalId":131383,"journal":{"name":"2020 Italian Conference on Optics and Photonics (ICOP)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Italian Conference on Optics and Photonics (ICOP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOP49690.2020.9300325","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Ultrafast lasers are increasing their range of applications. In non-linear optical microscopy, the laser beam properties can influence the non-linear contrast efficiency and the image quality, so monitoring of the output waveform is often required.In order to obtain images, in Stimulated Raman Scattering (SRS) microscopy, two collinear laser beams, a high-power pump laser and a low power Stokes laser with different frequencies (ωL> ωS) are focused into a sample. In this paper the two laser sources, in our case a femtosecond Ti:Sapphire (Ti:Sa) oscillator and a femtosecond synchronized optical parametric oscillator (OPO) are characterized by non-linear interferometric measurements. Taking advantage of two-photon absorption (TPA), autocorrelation measurements of each laser beam and cross correlation measurements of Ti:Sa and OPO are carried out. Results are reported and discussed.