Dry contact electrodes performance in canine ECG

J. Virtanen, Joni Leivo, A. Vehkaoja, Sanni Somppi, Heini Törnqvist, P. Fiedler, H. Väätäjä, Veikko Surakka
{"title":"Dry contact electrodes performance in canine ECG","authors":"J. Virtanen, Joni Leivo, A. Vehkaoja, Sanni Somppi, Heini Törnqvist, P. Fiedler, H. Väätäjä, Veikko Surakka","doi":"10.1145/3295598.3295609","DOIUrl":null,"url":null,"abstract":"Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 - ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.","PeriodicalId":233211,"journal":{"name":"Proceedings of the Fifth International Conference on Animal-Computer Interaction","volume":"35 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-12-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Fifth International Conference on Animal-Computer Interaction","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3295598.3295609","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 - ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
干接触电极在犬心电图中的表现
测量动物的心率是一个重要的研究领域,可以应用于许多分析。在这项工作中,我们评估了用于监测家养宠物心率的两种干接触心电图(ECG)电极结构的性能。目的是通过一些修改来改进先前评估的电极的操作。首先,先前研究的带有银/氯化银(Ag/AgCl)涂层的聚合物电极的30针减少到12针。其次,用聚(3,4 -乙烯二氧噻吩)聚苯乙烯磺酸盐(PEDOT:PSS)涂覆12针镀金金属电极。这些电极连接在一个专门设计的测量线束上,电极的性能根据心跳检测覆盖范围进行评估。在站立、坐着、躺着和行走四种不同的行为中测量心率覆盖率(N=27/活动)。总的来说,结果与先前报道的性能相当,但在聚合物电极上较少的引脚似乎会导致覆盖值的更多变化。然而,当考虑到覆盖率的中值等度量时,没有明显的差异,特别是当覆盖值被全部观察时。因此,新的电极溶液值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信