{"title":"Technique for assessing PNA measurement repeatability using a NIST standard","authors":"Nazia Akil, B. Grossman","doi":"10.1109/ARFTG.2005.8373123","DOIUrl":null,"url":null,"abstract":"A method is demonstrated where by the use of the NIST (National Institute of Standards and Technology) reference material 8130 and NIST MultiCal® software allow the performance of modern performance network analyzers (PNA) to be evaluated and compared to a NIST benchmark TRL calibration. The analysis, presented here, is useful in the assessment of calibration repeatability. It also yields information to help improve the comparison of VNA measurement results from across various Intel laboratories.","PeriodicalId":444012,"journal":{"name":"2005 66th ARFTG Microwave Measurement Conference (ARFTG)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 66th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG.2005.8373123","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A method is demonstrated where by the use of the NIST (National Institute of Standards and Technology) reference material 8130 and NIST MultiCal® software allow the performance of modern performance network analyzers (PNA) to be evaluated and compared to a NIST benchmark TRL calibration. The analysis, presented here, is useful in the assessment of calibration repeatability. It also yields information to help improve the comparison of VNA measurement results from across various Intel laboratories.
使用NIST标准评估PNA测量可重复性的技术
通过使用NIST(国家标准与技术研究所)参考材料8130和NIST multic®软件,演示了一种方法,该方法允许评估现代性能网络分析仪(PNA)的性能,并与NIST基准TRL校准进行比较。本文提出的分析对校准可重复性的评估是有用的。它还提供信息,以帮助改进来自不同英特尔实验室的VNA测量结果的比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信