{"title":"Mixer Residual Phase Noise Measurements Using Clock-locked DDS Sources and Receivers","authors":"J. Dunsmore, J. Iwai","doi":"10.1109/ARFTG52954.2022.9844065","DOIUrl":null,"url":null,"abstract":"Methods for residual measurements on mixers are difficult and require at least one other mixer making it difficult to separate the residual effects between them. Here we introduce a novel scheme that uses a system completely clocked off a single reference oscillator using pairs of DDS sources to produce an input and LO signal as well as a third DDS source to re-convert the mixer output We show the close-in phase noise is largely canceled with this method resulting in a good measure of the mixer residual phase noise somewhat independent of the raw phase noise of the DDS sources. This improvement can also be shown for close-in residual measurements of amplifiers.","PeriodicalId":266876,"journal":{"name":"2022 98th ARFTG Microwave Measurement Conference (ARFTG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-01-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 98th ARFTG Microwave Measurement Conference (ARFTG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ARFTG52954.2022.9844065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Methods for residual measurements on mixers are difficult and require at least one other mixer making it difficult to separate the residual effects between them. Here we introduce a novel scheme that uses a system completely clocked off a single reference oscillator using pairs of DDS sources to produce an input and LO signal as well as a third DDS source to re-convert the mixer output We show the close-in phase noise is largely canceled with this method resulting in a good measure of the mixer residual phase noise somewhat independent of the raw phase noise of the DDS sources. This improvement can also be shown for close-in residual measurements of amplifiers.
使用时钟锁定DDS源和接收机的混频器剩余相位噪声测量
对混频器进行残留测量的方法是困难的,并且需要至少一个其他混频器,使得难以在它们之间分离残留效应。在这里,我们介绍了一种新的方案,该方案使用一个完全关闭单个参考振荡器的系统,使用对DDS源来产生输入和LO信号,以及第三个DDS源来重新转换混频器输出。我们表明,通过这种方法,接近相位噪声在很大程度上被抵消了,从而很好地测量了混频器剩余相位噪声,在某种程度上独立于DDS源的原始相位噪声。这种改进也可用于放大器的近端残余测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信