APLIKASI LOAD CELL UNTUK SISTEM MONITORING VOLUME CAIRAN INFUS

Diana Lestariningsih, Hartono Pranjoto, Lanny Agustine, Y. D. W. Werdani, Benedictus Teja
{"title":"APLIKASI LOAD CELL UNTUK SISTEM MONITORING VOLUME CAIRAN INFUS","authors":"Diana Lestariningsih, Hartono Pranjoto, Lanny Agustine, Y. D. W. Werdani, Benedictus Teja","doi":"10.21831/jps.v26i1.34441","DOIUrl":null,"url":null,"abstract":"Infusion is very important for patients who need additional fluids in the body. Intravenous fluids are injected into the body using needles, through veins. Delayed replacement of IV fluids can pose a very high risk for the patient's condition. One of the risk is that the blood can be sucked back and flow in the IV tube, because there is a difference fluid pressure between the vein and the infusion bag. Therefore, controlling the volume of infusion fluid is very necessary so the infusion bag containing the intravenous fluid must not be used up.To minimize the risk is by replacing the IV bag that must be done in a timely manner. So to find out the amount of infusion fluid volume in the infusion bag it will be designed and realized an instrument that can measure the volume of infusion fluid by weighing the weight of the infusion bag. This tool can stop the flow of IV fluids that flow into veins when the IV fluid will be depleted.The result of this research is that the system will stop the infusion fluid flow by activating the pinch valve by clamping the infusion hose so that the fluid can stop when the infusion fluid volume will run out. Discontinuation of infusion fluid occurs when the remaining infusion fluid volume is 10 mL","PeriodicalId":370796,"journal":{"name":"Jurnal Penelitian Saintek","volume":"2015 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Penelitian Saintek","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21831/jps.v26i1.34441","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Infusion is very important for patients who need additional fluids in the body. Intravenous fluids are injected into the body using needles, through veins. Delayed replacement of IV fluids can pose a very high risk for the patient's condition. One of the risk is that the blood can be sucked back and flow in the IV tube, because there is a difference fluid pressure between the vein and the infusion bag. Therefore, controlling the volume of infusion fluid is very necessary so the infusion bag containing the intravenous fluid must not be used up.To minimize the risk is by replacing the IV bag that must be done in a timely manner. So to find out the amount of infusion fluid volume in the infusion bag it will be designed and realized an instrument that can measure the volume of infusion fluid by weighing the weight of the infusion bag. This tool can stop the flow of IV fluids that flow into veins when the IV fluid will be depleted.The result of this research is that the system will stop the infusion fluid flow by activating the pinch valve by clamping the infusion hose so that the fluid can stop when the infusion fluid volume will run out. Discontinuation of infusion fluid occurs when the remaining infusion fluid volume is 10 mL
输液对需要补充体液的病人非常重要。静脉注射液体是用针通过静脉注入体内的。延迟更换静脉输液会对患者的病情造成非常高的风险。其中一个风险是血液可能被吸回并在静脉管中流动,因为静脉和输液袋之间的流体压力存在差异。因此,控制输液的体积是非常必要的,这样就不能用完装有静脉输液的输液袋。为了将风险降到最低,必须及时更换静脉输液袋。因此,为了了解输液袋中输液体积的大小,我们设计并实现了一种通过称重输液袋的重量来测量输液体积的仪器。当静脉注射液耗尽时,这个工具可以阻止静脉注射液流入静脉。本研究的结果是,该系统通过夹紧输液管激活夹管阀,使输液液停止流动,当输液量即将用完时即可停止输液液。当剩余输液液量为10ml时停止输液液
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信