The Study on Effect of Colour Electrolyte Reference Electrode

H. Mamat, A. Tuhaime, A. Jalar
{"title":"The Study on Effect of Colour Electrolyte Reference Electrode","authors":"H. Mamat, A. Tuhaime, A. Jalar","doi":"10.1109/ICOS.2018.8632702","DOIUrl":null,"url":null,"abstract":"The function of the reference electrode is to complete the pH measurement circuit, in conjunction with pH sensor. This paper described the characterization of in-house Reference Electrode (RE) using green colour electrolyte as a medium. The in-house RE was tested with few subjects such as commercial RE, in-house Nitrate Sensor, and in-house pH sensor. The study is focusing on the effect and stability of colour electrolyte using in RE. The result shows In-house reference electrode with coloured electrolyte performed a very stable output. Total of 3 experiment done shows the RE are able to detect different pH (buffer solution) and provide a good slope R2near to 1. Furthermore, the field testing shows the colour electrolyte able to improve the voltage reading and minimize drift effect.","PeriodicalId":412535,"journal":{"name":"2018 IEEE Conference on Open Systems (ICOS)","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Conference on Open Systems (ICOS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICOS.2018.8632702","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The function of the reference electrode is to complete the pH measurement circuit, in conjunction with pH sensor. This paper described the characterization of in-house Reference Electrode (RE) using green colour electrolyte as a medium. The in-house RE was tested with few subjects such as commercial RE, in-house Nitrate Sensor, and in-house pH sensor. The study is focusing on the effect and stability of colour electrolyte using in RE. The result shows In-house reference electrode with coloured electrolyte performed a very stable output. Total of 3 experiment done shows the RE are able to detect different pH (buffer solution) and provide a good slope R2near to 1. Furthermore, the field testing shows the colour electrolyte able to improve the voltage reading and minimize drift effect.
彩色电解液参比电极作用的研究
参比电极的作用是配合pH传感器完成pH测量电路。本文描述了以绿色电解质为介质的内部参比电极(RE)的表征。采用商用稀土、内部硝酸盐传感器和内部pH传感器等少数测试对象对内部稀土进行了测试。研究了彩色电解液在稀土中使用的效果和稳定性。结果表明,使用彩色电解液的内部参比电极输出非常稳定。总共3个实验表明,RE能够检测不同的pH值(缓冲溶液),并提供接近1的良好斜率r2。此外,现场测试表明,彩色电解液能够提高电压读数,最大限度地减少漂移效应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信