Heart Sound Feature Parameters Distribution and Support Vector Machine-Based Classification Boundary Determination Method for Ventricular Septal Defect Auscultation

Shuping Sun, Zhongwei Jiang, Haibin Wang, Yu Fang, Ting Tao
{"title":"Heart Sound Feature Parameters Distribution and Support Vector Machine-Based Classification Boundary Determination Method for Ventricular Septal Defect Auscultation","authors":"Shuping Sun, Zhongwei Jiang, Haibin Wang, Yu Fang, Ting Tao","doi":"10.1299/JCST.6.198","DOIUrl":null,"url":null,"abstract":"This paper is concerned with a novel proposal to determinate classification boundaries both in time and frequency domains based on the support vector machines (SVM) technique for diagnosis of ventricular septal defect (VSD). Firstly, two heart sound characteristic waveforms are extracted both from time-domain and frequency-domain. Four heart sound feature parameters both in time and frequency domains, [ T 11 , T 12 ] and [ F G , F W ], are obtained from the crossed points of the waveforms at the selected threshold values. Secondly, a novel algorithm to determine the classification boundaries surrounding the feature parameters is proposed with the aid of SVM technique for evaluating the performance of VSD auscultation. Finally, the classification labeling indexes based on the classification boundaries are introduced for diagnosis of VSD. A case study on the normal and VSD cases is demonstrated to validate the usefulness and e ffi ciency of the proposed method; the classification accuracy (CA) is gained 98.4% for diagnosing VSD from the normal cases. Furthermore, the proposed method is applied to classify the sizes of the defect in VSD. The accuracies have been achieved at 94 . 9% for small, 93 . 6% for moderate and 95 . 8% for large VSD. heart sound samples, and the results showed that the accuracies are 98 . 4% for classification of VSD from normal sounds, 94 . 9% for SVSD from other VSD sounds, 93 . 6% for MVSD and 95 . 8% for LVSD, respectively. Furthermore, the methodology proposed in this paper shows a high potential to be extended to the other heart disorder diagnosis.","PeriodicalId":196913,"journal":{"name":"Journal of Computational Science and Technology","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Computational Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1299/JCST.6.198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This paper is concerned with a novel proposal to determinate classification boundaries both in time and frequency domains based on the support vector machines (SVM) technique for diagnosis of ventricular septal defect (VSD). Firstly, two heart sound characteristic waveforms are extracted both from time-domain and frequency-domain. Four heart sound feature parameters both in time and frequency domains, [ T 11 , T 12 ] and [ F G , F W ], are obtained from the crossed points of the waveforms at the selected threshold values. Secondly, a novel algorithm to determine the classification boundaries surrounding the feature parameters is proposed with the aid of SVM technique for evaluating the performance of VSD auscultation. Finally, the classification labeling indexes based on the classification boundaries are introduced for diagnosis of VSD. A case study on the normal and VSD cases is demonstrated to validate the usefulness and e ffi ciency of the proposed method; the classification accuracy (CA) is gained 98.4% for diagnosing VSD from the normal cases. Furthermore, the proposed method is applied to classify the sizes of the defect in VSD. The accuracies have been achieved at 94 . 9% for small, 93 . 6% for moderate and 95 . 8% for large VSD. heart sound samples, and the results showed that the accuracies are 98 . 4% for classification of VSD from normal sounds, 94 . 9% for SVSD from other VSD sounds, 93 . 6% for MVSD and 95 . 8% for LVSD, respectively. Furthermore, the methodology proposed in this paper shows a high potential to be extended to the other heart disorder diagnosis.
基于支持向量机的室间隔缺损听诊心音特征参数分布及分类边界确定方法
本文提出了一种基于支持向量机(SVM)技术的室间隔缺损诊断的时域和频域分类边界确定方法。首先在时域和频域分别提取两个心音特征波形;从所选阈值处的波形交叉点得到时域和频域的四个心音特征参数[t11, t12]和[gf, fw]。其次,结合支持向量机技术,提出了一种新的VSD听诊性能评价算法,确定特征参数周围的分类边界。最后,介绍了基于分类边界的VSD分类标记指标。通过对正常和VSD情况的分析,验证了该方法的有效性;诊断VSD的准确率(CA)为98.4%。并将该方法应用于VSD缺陷的尺寸分类。精度已达到94。小的占9%,93%。中等和95分为6%。大VSD为8%。心音采样,结果表明准确率为98。4%的人认为VSD与正常声音的区别,94分。9%的SVSD来自其他VSD声音,93。6%为MVSD, 95%。LVSD分别为8%。此外,本文提出的方法在其他心脏疾病的诊断中显示出很高的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信