{"title":"RADFET utilization for spacecraft dosimetry","authors":"Y. Kimoto, A. Jaksic","doi":"10.1109/ICMEL.2004.1314914","DOIUrl":null,"url":null,"abstract":"This paper describes the total dose effect measurement systems mounted aboard the MDS-1 satellite, in particular the dosimetric system utilizing RADFET devices. Ground calibration results and initial flight data are presented.","PeriodicalId":202761,"journal":{"name":"2004 24th International Conference on Microelectronics (IEEE Cat. No.04TH8716)","volume":"66 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2004-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2004 24th International Conference on Microelectronics (IEEE Cat. No.04TH8716)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICMEL.2004.1314914","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
This paper describes the total dose effect measurement systems mounted aboard the MDS-1 satellite, in particular the dosimetric system utilizing RADFET devices. Ground calibration results and initial flight data are presented.