Field evaluation of the Becton-Dickinson SST.

Health laboratory science Pub Date : 1976-07-01
R H Laessig, R N Carey, J O Westgard, D J Hassemer, R Habig
{"title":"Field evaluation of the Becton-Dickinson SST.","authors":"R H Laessig,&nbsp;R N Carey,&nbsp;J O Westgard,&nbsp;D J Hassemer,&nbsp;R Habig","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The Becton-Dickinson VACUTAINER BRAND SERUM SEPARATOR TUBE (SST) was evaluated in a field test in five hospitals. The SST evacuated blood drawing tube contains a semi-solid silicon polymer which migrates to the serum-clot interface during centrifugation causing a barrier to form which separates serum from red cells. Eighteen clinical chemistry determinations were studied. No clinically significant SST induced changes were observed when compared to conventional blood drawing tubes. Statistically significant changes (t-test, p=0.05) were observed for bicarbonate, calcium, chloride, cholesterol, glucose (Beckman Analyzer), and sodium. For each test (glucose, uric acid, etc.) data were analyzed twice; once as a complete set, and once as a subset consisting of abnormal data only. The small, statistically significant LDH bias observed in the earlier (2,3) clinical trials was not present.</p>","PeriodicalId":12869,"journal":{"name":"Health laboratory science","volume":"13 3","pages":"209-17"},"PeriodicalIF":0.0000,"publicationDate":"1976-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health laboratory science","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Becton-Dickinson VACUTAINER BRAND SERUM SEPARATOR TUBE (SST) was evaluated in a field test in five hospitals. The SST evacuated blood drawing tube contains a semi-solid silicon polymer which migrates to the serum-clot interface during centrifugation causing a barrier to form which separates serum from red cells. Eighteen clinical chemistry determinations were studied. No clinically significant SST induced changes were observed when compared to conventional blood drawing tubes. Statistically significant changes (t-test, p=0.05) were observed for bicarbonate, calcium, chloride, cholesterol, glucose (Beckman Analyzer), and sodium. For each test (glucose, uric acid, etc.) data were analyzed twice; once as a complete set, and once as a subset consisting of abnormal data only. The small, statistically significant LDH bias observed in the earlier (2,3) clinical trials was not present.

Becton-Dickinson海温的现场评估。
在5家医院的现场试验中对Becton-Dickinson VACUTAINER牌血清分离管(SST)进行了评价。SST真空抽血管含有半固态硅聚合物,在离心过程中迁移到血清-凝块界面,形成屏障,将血清与红细胞分离。对18项临床化学指标进行了研究。与常规抽血管相比,未观察到SST引起的临床显著变化。碳酸氢盐、钙、氯化物、胆固醇、葡萄糖(Beckman分析仪)和钠的含量变化有统计学意义(t检验,p=0.05)。每项试验(葡萄糖、尿酸等)数据分析2次;一次作为一个完整的集合,一次作为一个仅由异常数据组成的子集。在早期(2,3)临床试验中观察到的小的、统计学上显著的LDH偏倚不存在。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信